Mass flow control using estimated output feedback in semiconductor processes

In the semiconductor manufacturing , process gas switching during atomic layer deposition and etching is critical for improving throughput. Thermal mass flow controller (MFC) used in this process requires a fast flow response. However, the slow response of thermal flow sensor leads to issue under transient conditions. Specifically, the observable flow value and the actual flow deviate, resulting in overshoot in the flow supplied to the chamber. To mitigate this issue, thermal flow response lag can be compensated through deviation operation. However, this method amplifies sensor noise and degrades flow stability, creating a trade-off between response time and stability. To address these challenges, this study proposes a feedback control system that employs an estimated output instead of direct sensor measurements, enabling a fast response with reduced noise and eliminating steady-state errors. The effectiveness of the proposed control scheme is validated experimentally.

Authors

Institutions

Publication Details

Journal
Mechatronics
Published
2025-04-26
DOI
https://doi.org/10.1016/j.mechatronics.2025.103320
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mass flow control using estimated output feedback in semiconductor processes

Daisuke Hayashi, Kotaro Takijiri, Kazuki Nakata
Mechatronics
Plasma Diagnostics and Applications
article

Mass flow control using estimated output feedback in semiconductor processes

Daisuke Hayashi, Kotaro Takijiri, Kazuki Nakata
article en

Abstract

In the semiconductor manufacturing , process gas switching during atomic layer deposition and etching is critical for improving throughput. Thermal mass flow controller (MFC) used in this process requires a fast flow response. However, the slow response of thermal flow sensor leads to issue under transient conditions. Specifically, the observable flow value and the actual flow deviate, resulting in overshoot in the flow supplied to the chamber. To mitigate this issue, thermal flow response lag can be compensated through deviation operation. However, this method amplifies sensor noise and degrades flow stability, creating a trade-off between response time and stability. To address these challenges, this study proposes a feedback control system that employs an estimated output instead of direct sensor measurements, enabling a fast response with reduced noise and eliminating steady-state errors. The effectiveness of the proposed control scheme is validated experimentally.

MechatronicsVol. 108
Horiba (Japan) (JP)
Affordable and clean energy
Openalex Percentile: Top 93%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.