Development and evaluation of a phantom for CBCT image quality control of dental hygienists

Objectives: We developed a phantom to assess the quality of cone-beam computed tomography (CBCT) images using materials commonly used in dentistry. This study aimed to raise awareness and promote ongoing education for dental hygienists in the f ield of CBCT image quality control. Methods: The phantom and instruments were scanned using CBCT at 80 kVp and 10 mA, with an exposure time of 17s. The images were evaluated for contrast resolution, uniformity, and metal artifacts. The acquired images were extracted and analyzed in the DICOM format using On-Demand 3D software. Results: The images showed various grayscale contrast across all five materials. Uniformity was measured in five regions of the phantom, with average gray scale values ranging from -81.2~-68.1. The evaluation of the metal artifacts revealed that the cylindrical titanium block exhibited the least magnification, whereas the triangular block exhibited the most. Conclusion: Dental hygienists should be aware that CBCT images may contain errors and focus on maintaining the image quality and engaging in continuous education.

Authors

Publication Details

Journal
Journal of Korean society of Dental Hygiene
Published
2025-04-26
DOI
https://doi.org/10.13065/jksdh.2025.25.2.4
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and evaluation of a phantom for CBCT image quality control of dental hygienists

Sae-Rom Lee, Ju-Hee Kang
Journal of Korean society of Dental Hygiene
Dental Radiography and Imaging
article

Development and evaluation of a phantom for CBCT image quality control of dental hygienists

Sae-Rom Lee, Ju-Hee Kang
article en

Abstract

Objectives: We developed a phantom to assess the quality of cone-beam computed tomography (CBCT) images using materials commonly used in dentistry. This study aimed to raise awareness and promote ongoing education for dental hygienists in the f ield of CBCT image quality control. Methods: The phantom and instruments were scanned using CBCT at 80 kVp and 10 mA, with an exposure time of 17s. The images were evaluated for contrast resolution, uniformity, and metal artifacts. The acquired images were extracted and analyzed in the DICOM format using On-Demand 3D software. Results: The images showed various grayscale contrast across all five materials. Uniformity was measured in five regions of the phantom, with average gray scale values ranging from -81.2~-68.1. The evaluation of the metal artifacts revealed that the cylindrical titanium block exhibited the least magnification, whereas the triangular block exhibited the most. Conclusion: Dental hygienists should be aware that CBCT images may contain errors and focus on maintaining the image quality and engaging in continuous education.

Journal of Korean society of Dental HygieneVol. 25(2)
Openalex Percentile: Top 88%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.