The human lens capsule is a robust, transparent basement membrane commonly discarded during cataract surgery. Although its use as a biological graft has gained interest in ocular surgery, practical methods for securing the capsule, such as suturing, have not been evaluated. This technical report presents the first in vitro assessment of anterior lens capsule sutureability using fine 10-0 sutures. Anterior capsule specimens were obtained from two patients with pseudoexfoliation syndrome undergoing routine cataract surgery. After being stored for four hours in balanced salt solution (BSS), the specimens, one stained with trypan blue and the other unstained, were spread on a plastic surface (a cellophane sheet: as a non-biologic backing substrate) and sutured using 10-0 nylon (Ethilon™, Ethicon, Raritan, NJ, USA) and 10-0 polyglactin 910 (Vicryl™, Ethicon, Raritan, NJ, USA) under an operating microscope. Both suture types could be successfully passed through the capsule without immediate tearing. The stained capsule enhanced visibility but appeared slightly more fragile, while the unstained capsule demonstrated greater elasticity. Attempts to reapproximate full-thickness capsule tears using sutures were unsuccessful. Viscoelastic agents, including MiniVisc® Plus (Bausch + Lomb, Vaughan, Canada) and DisCoVisc® (Alcon Laboratories, Fort Worth, TX, USA), did not aid in capsule stabilization and reduced visibility during manipulation. No specialized instruments beyond standard ophthalmic tools were used. These findings demonstrate that human anterior lens capsules can tolerate fine suturing in vitro and suggest their potential as suturable biological grafts in applications such as corneal patching, pterygium surgery, or ocular surface reconstruction. However, limitations in tear repair and in vivo behavior require further investigation to establish clinical utility.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-04-26
DOI
https://doi.org/10.7759/cureus.83028
Citations
1
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
1.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ex Vivo Microsuturing of the Human Anterior Lens Capsule Using 10-0 Sutures: A Technical Feasibility Report

Joobin Khadamy, Pontus Lithén
1 citations
Cureus
Intraocular Surgery and Lenses
1.71
article

Ex Vivo Microsuturing of the Human Anterior Lens Capsule Using 10-0 Sutures: A Technical Feasibility Report

Joobin Khadamy, Pontus Lithén
article en
1 citations

Abstract

The human lens capsule is a robust, transparent basement membrane commonly discarded during cataract surgery. Although its use as a biological graft has gained interest in ocular surgery, practical methods for securing the capsule, such as suturing, have not been evaluated. This technical report presents the first in vitro assessment of anterior lens capsule sutureability using fine 10-0 sutures. Anterior capsule specimens were obtained from two patients with pseudoexfoliation syndrome undergoing routine cataract surgery. After being stored for four hours in balanced salt solution (BSS), the specimens, one stained with trypan blue and the other unstained, were spread on a plastic surface (a cellophane sheet: as a non-biologic backing substrate) and sutured using 10-0 nylon (Ethilon™, Ethicon, Raritan, NJ, USA) and 10-0 polyglactin 910 (Vicryl™, Ethicon, Raritan, NJ, USA) under an operating microscope. Both suture types could be successfully passed through the capsule without immediate tearing. The stained capsule enhanced visibility but appeared slightly more fragile, while the unstained capsule demonstrated greater elasticity. Attempts to reapproximate full-thickness capsule tears using sutures were unsuccessful. Viscoelastic agents, including MiniVisc® Plus (Bausch + Lomb, Vaughan, Canada) and DisCoVisc® (Alcon Laboratories, Fort Worth, TX, USA), did not aid in capsule stabilization and reduced visibility during manipulation. No specialized instruments beyond standard ophthalmic tools were used. These findings demonstrate that human anterior lens capsules can tolerate fine suturing in vitro and suggest their potential as suturable biological grafts in applications such as corneal patching, pterygium surgery, or ocular surface reconstruction. However, limitations in tear repair and in vivo behavior require further investigation to establish clinical utility.

CureusVol. 17(4)
Skellefteå Hospital (SE), Umeå University (SE)
Zero hunger
Openalex Percentile: Top 19%
Intraocular Surgery and Lenses
1.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ex Vivo Microsuturing of the Human Anterior Lens Capsule Using 10-0 Sutures: A Technical Feasibility Report — Joobin Khadamy, Pontus Lithén · Cureus (2025) | TGRS Research Map | TGRS