Performance Evaluation of a Glazed Transpired Solar Collector with Chimney in Natural Convection Mode

Transpired solar collectors require adequate pressure difference across them to work and electric fans usually produce the pressure difference in forced convection mode. In natural convection mode no fan is used and little or no pressure is produced across the collector. A chimney can replace the fan in natural convection mode and buoyancy forces in the chimney and collector produce pressure difference across the collector. An experimental rig was set up in the field to study a glazed transpired solar collector (GTC) with chimney in natural convection mode. The chimney height range was 4.04m to 8.04m while absorber hole diameter range was 1.0mm to 3.0mm. The study considered the influence of absorber hole diameter, collector air velocity and chimney height on the performance of the GTC. Results showed that heat exchange effectiveness decreased from 0.97 at absorber hole diameter of 1.0mm to 0.78 at absorber hole diameter of 3.0mm. Thermal efficiency increased from 6% at absorber hole diameter of 1.0mm to 75.4% at absorber hole diameter of 3.0mm. The efficiency also increased from 16.5% at a pressure difference of 6.81N/m2 corresponding to a chimney height of 4.04m to 75.2% at a pressure difference of 14.11N/m2 corresponding to a chimney height of 8.04m for the absorber with hole diameter of 3.0mm. The collector outlet velocity increased from 0.045m/s at a chimney dimensionless height of 11.74 to 0.075m/s at a chimney dimensionless height of 23.44 for an absorber hole diameter of 3.0mm. Finally, the pressure difference across the absorber increased from 6.81N/m2 at a chimney dimensionless height of 11.74 to 14.11N/m2 at a chimney dimensionless height of 24.31. The thermal efficiency and heat exchange effectiveness obtained in this study show that the GTC with chimney has promise for application in the areas of space heating and crop drying in natural convection mode.

Authors

Publication Details

Journal
Journal of Energy Research and Reviews
Published
2025-04-26
DOI
https://doi.org/10.9734/jenrr/2025/v17i5414
Primary Topic
Solar Energy Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of a Glazed Transpired Solar Collector with Chimney in Natural Convection Mode

Matthew Ekoja, O. V. Ekechukwu, S.O. Onyegegbu
Journal of Energy Research and Reviews
Solar Energy Systems and Technologies
article

Performance Evaluation of a Glazed Transpired Solar Collector with Chimney in Natural Convection Mode

Matthew Ekoja, O. V. Ekechukwu, S.O. Onyegegbu
article en

Abstract

Transpired solar collectors require adequate pressure difference across them to work and electric fans usually produce the pressure difference in forced convection mode. In natural convection mode no fan is used and little or no pressure is produced across the collector. A chimney can replace the fan in natural convection mode and buoyancy forces in the chimney and collector produce pressure difference across the collector. An experimental rig was set up in the field to study a glazed transpired solar collector (GTC) with chimney in natural convection mode. The chimney height range was 4.04m to 8.04m while absorber hole diameter range was 1.0mm to 3.0mm. The study considered the influence of absorber hole diameter, collector air velocity and chimney height on the performance of the GTC. Results showed that heat exchange effectiveness decreased from 0.97 at absorber hole diameter of 1.0mm to 0.78 at absorber hole diameter of 3.0mm. Thermal efficiency increased from 6% at absorber hole diameter of 1.0mm to 75.4% at absorber hole diameter of 3.0mm. The efficiency also increased from 16.5% at a pressure difference of 6.81N/m2 corresponding to a chimney height of 4.04m to 75.2% at a pressure difference of 14.11N/m2 corresponding to a chimney height of 8.04m for the absorber with hole diameter of 3.0mm. The collector outlet velocity increased from 0.045m/s at a chimney dimensionless height of 11.74 to 0.075m/s at a chimney dimensionless height of 23.44 for an absorber hole diameter of 3.0mm. Finally, the pressure difference across the absorber increased from 6.81N/m2 at a chimney dimensionless height of 11.74 to 14.11N/m2 at a chimney dimensionless height of 24.31. The thermal efficiency and heat exchange effectiveness obtained in this study show that the GTC with chimney has promise for application in the areas of space heating and crop drying in natural convection mode.

Journal of Energy Research and ReviewsVol. 17(5)
Openalex Percentile: Top 92%
Solar Energy Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.