Endoscopic Wire-Assisted Closure of Enteric Fistulae

Introduction: Historically, the treatment of enteric fistula required surgical intervention, often exposing patients to complex surgeries and a high risk of fistula recurrence. With advancements in endoscopic therapies, successful closure of enteric fistula using over-the-scope (OTS) clips can be as high as 85%.1 A previous study demonstrated the safety and efficacy of firing OTS clips over a wire, which allows the endoscopist to improve the maneuverability of the endoscope and obtain appropriate apposition of the OTS clip to the fistula opening.2 This video documents two obscure enteric fistulae and the use of a flexible guidewire to facilitate the application of an OTS clip. We demonstrate that firing an OTS clip over a wire is safe, with easy removal of the wire following clip placement.

Authors

Institutions

Publication Details

Journal
Videoscopy
Published
2025-03-01
DOI
https://doi.org/10.1089/vor.2025.0006
Primary Topic
Esophageal and GI Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endoscopic Wire-Assisted Closure of Enteric Fistulae

McKell Quattrone, E. L. Moyer
Videoscopy
Esophageal and GI Pathology
article

Endoscopic Wire-Assisted Closure of Enteric Fistulae

McKell Quattrone, E. L. Moyer
article en

Abstract

Introduction: Historically, the treatment of enteric fistula required surgical intervention, often exposing patients to complex surgeries and a high risk of fistula recurrence. With advancements in endoscopic therapies, successful closure of enteric fistula using over-the-scope (OTS) clips can be as high as 85%.1 A previous study demonstrated the safety and efficacy of firing OTS clips over a wire, which allows the endoscopist to improve the maneuverability of the endoscope and obtain appropriate apposition of the OTS clip to the fistula opening.2 This video documents two obscure enteric fistulae and the use of a flexible guidewire to facilitate the application of an OTS clip. We demonstrate that firing an OTS clip over a wire is safe, with easy removal of the wire following clip placement.

VideoscopyVol. 35(1)
Penn State Milton S. Hershey Medical Center (US)
Zero hunger
Openalex Percentile: Top 85%
Esophageal and GI Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.