Development of anti-fouling endoscope tip hood for gastrointestinal endoscopy

The contamination of the endoscope tip lens results in poor endoscopic imaging. To prevent the adsorption of contaminants, we applied a soft contact lens made of 2-hydroxyethyl methacrylate hydrogel to the tip of a gastrointestinal endoscope. Additionally, a novel endoscopic hood with an upper surface composed of a single layer inside the hood cavity was developed. For in vitro anti-fouling performance testing using blood, changes in light transmittance were examined with hydrogel plates and compared to conventional quartz glass and surfactant-coated glass. The transmittance changes at a wavelength of 415 nm were 1.5% for the hydrogel plate, significantly lower than 82.9% for quartz glass and 85.2% for surfactant-coated glass (p < 0.001), demonstrating the hydrogel's high anti-fouling performance. Another in vitro quantitative assay, evaluated by exposure to blood, lipid, and mucin liquids, showed high anti-fouling performance in the order hydrogel plate > surfactant-coated glass > quartz glass. Moreover, an in vivo pig model performing gastric endoscopic submucosal dissection was used to evaluate anti-fouling performance by analyzing endoscopic images with Michelson contrast. The contrast value of the upper surface group (Hydrogel) was 0.97, significantly higher than 0.62 for the non-upper surface group (Surfactant) (P < 0.001). Therefore, the novel anti-fouling endoscope tip hood could be applied in future clinical applications.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-25
DOI
https://doi.org/10.1038/s41598-025-92118-1
Citations
1
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of anti-fouling endoscope tip hood for gastrointestinal endoscopy

Madoka Takao, Yuzo Kodama, Yoshinori Morita, Shiori Hino et al.
1 citations
Scientific Reports
Gastrointestinal Bleeding Diagnosis and Treatment
1.81
article

Development of anti-fouling endoscope tip hood for gastrointestinal endoscopy

Madoka Takao, Yuzo Kodama, Yoshinori Morita, Shiori Hino, Yusaku Shimamoto, Toru Matsunaga, Takao Sato
article en
1 citations

Abstract

The contamination of the endoscope tip lens results in poor endoscopic imaging. To prevent the adsorption of contaminants, we applied a soft contact lens made of 2-hydroxyethyl methacrylate hydrogel to the tip of a gastrointestinal endoscope. Additionally, a novel endoscopic hood with an upper surface composed of a single layer inside the hood cavity was developed. For in vitro anti-fouling performance testing using blood, changes in light transmittance were examined with hydrogel plates and compared to conventional quartz glass and surfactant-coated glass. The transmittance changes at a wavelength of 415 nm were 1.5% for the hydrogel plate, significantly lower than 82.9% for quartz glass and 85.2% for surfactant-coated glass (p < 0.001), demonstrating the hydrogel's high anti-fouling performance. Another in vitro quantitative assay, evaluated by exposure to blood, lipid, and mucin liquids, showed high anti-fouling performance in the order hydrogel plate > surfactant-coated glass > quartz glass. Moreover, an in vivo pig model performing gastric endoscopic submucosal dissection was used to evaluate anti-fouling performance by analyzing endoscopic images with Michelson contrast. The contrast value of the upper surface group (Hydrogel) was 0.97, significantly higher than 0.62 for the non-upper surface group (Surfactant) (P < 0.001). Therefore, the novel anti-fouling endoscope tip hood could be applied in future clinical applications.

Scientific ReportsVol. 15(1)
Kobe International University (JP), Seiko Holdings (Japan) (JP), Kobe University (JP)
Japan Agency for Medical Research and Development
Zero hunger
Openalex Percentile: Top 18%
Gastrointestinal Bleeding Diagnosis and Treatment
1.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of anti-fouling endoscope tip hood for gastrointestinal endoscopy — Madoka Takao, Yuzo Kodama, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS