A Novel Technique for Retrieval of Dislodged Coronary Stent from Renal Artery: A Case Report

Coronary artery stent (CAS) dislodgment is a rare complication in contemporary percutaneous coronary intervention (PCI), with migration to the renal artery being exceedingly uncommon. Herein, we present a case report of a 78-year-old female patient who was transferred to a PCI hub center after an unsuccessful PCI of the left anterior descending artery at a spoke center, leading to CAS migration to the left coronary cusp of the aortic valve. During retrieval, the stent further dislodged into the left inferior segmental renal artery. Multiple standard retrieval techniques failed, but the SpiderFX embolic protection device was eventually employed, successfully recovering the stent. Limited data exists on CAS dislodgment within the renal artery, with only two cases reported in the literature, highlighting the need for broader awareness of this rare complication. Although snare loop and distal balloon inflating technique are standard for stent retrieval, they may not always suffice. In these instances, the SpiderFX device may be effective for renal artery stent retrieval.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2025-04-24
DOI
https://doi.org/10.1002/ccd.31548
Primary Topic
Renal and Vascular Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Technique for Retrieval of Dislodged Coronary Stent from Renal Artery: A Case Report

Marko Atanasković, Tihomir Miljević, M Kovacevic, Branislav Crnomarković
Catheterization and Cardiovascular Interventions
Renal and Vascular Pathologies
article

A Novel Technique for Retrieval of Dislodged Coronary Stent from Renal Artery: A Case Report

Marko Atanasković, Tihomir Miljević, M Kovacevic, Branislav Crnomarković
article en

Abstract

Coronary artery stent (CAS) dislodgment is a rare complication in contemporary percutaneous coronary intervention (PCI), with migration to the renal artery being exceedingly uncommon. Herein, we present a case report of a 78-year-old female patient who was transferred to a PCI hub center after an unsuccessful PCI of the left anterior descending artery at a spoke center, leading to CAS migration to the left coronary cusp of the aortic valve. During retrieval, the stent further dislodged into the left inferior segmental renal artery. Multiple standard retrieval techniques failed, but the SpiderFX embolic protection device was eventually employed, successfully recovering the stent. Limited data exists on CAS dislodgment within the renal artery, with only two cases reported in the literature, highlighting the need for broader awareness of this rare complication. Although snare loop and distal balloon inflating technique are standard for stent retrieval, they may not always suffice. In these instances, the SpiderFX device may be effective for renal artery stent retrieval.

Catheterization and Cardiovascular InterventionsVol. 106(1)
University of Novi Sad (RS), Institute for Cardiovascular Diseases of Vojvodina (RS)
Good health and well-being
Openalex Percentile: Top 86%
Renal and Vascular Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Technique for Retrieval of Dislodged Coronary Stent from Renal Artery: A Case Report — Marko Atanasković, Tihomir Miljević, et al. · Catheterization and Cardiovascular Interventions (2025) | TGRS Research Map | TGRS