Advanced Solid Phase Extraction Tools for Measuring Bempedoic Acid and its Active Metabolite in Human Plasma by Using LC-MS/MS

Aim/Background: To simultaneously measure bempedoic acid and its primary metabolite, bempedoic acid metabolite-ESP15228, in human plasma via UPLC-MS/MS, the QuEChERS extraction tactic is not suitable. Instead, employ a tailored bioanalytical approach. Materials and Methods: The QuEChERS technique was employed to extract human plasma, followed by analysis using LC-MS/MS. Separation of compounds was attained using a Zorbax C18 analytical column (50 mm×2.1 mm, 1.7 μm), with retention times of 4.35 and 5.58 min, respectively. The mobile phase consisted of acetonitrile (80%) and 10 mm ammonium acetate (20%), flowing at a rate of 0.80 mL/min. Ionization of the analyte occurred in the TQD

Authors

Institutions

Publication Details

Journal
Indian Journal of Pharmaceutical Education and Research
Published
2025-04-24
DOI
https://doi.org/10.5530/ijper.20257284
Citations
1
Primary Topic
Chemical synthesis and alkaloids
Type
article
Field-Weighted Citation Impact
0.94
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Solid Phase Extraction Tools for Measuring Bempedoic Acid and its Active Metabolite in Human Plasma by Using LC-MS/MS

N. Devanna, Mahesh Meghavath
1 citations
Indian Journal of Pharmaceutical Education and Research
Chemical synthesis and alkaloids
0.94
article

Advanced Solid Phase Extraction Tools for Measuring Bempedoic Acid and its Active Metabolite in Human Plasma by Using LC-MS/MS

N. Devanna, Mahesh Meghavath
article en
1 citations

Abstract

Aim/Background: To simultaneously measure bempedoic acid and its primary metabolite, bempedoic acid metabolite-ESP15228, in human plasma via UPLC-MS/MS, the QuEChERS extraction tactic is not suitable. Instead, employ a tailored bioanalytical approach. Materials and Methods: The QuEChERS technique was employed to extract human plasma, followed by analysis using LC-MS/MS. Separation of compounds was attained using a Zorbax C18 analytical column (50 mm×2.1 mm, 1.7 μm), with retention times of 4.35 and 5.58 min, respectively. The mobile phase consisted of acetonitrile (80%) and 10 mm ammonium acetate (20%), flowing at a rate of 0.80 mL/min. Ionization of the analyte occurred in the TQD

Indian Journal of Pharmaceutical Education and ResearchVol. 59(2s)
Jawaharlal Nehru Technological University Anantapur (IN)
Openalex Percentile: Top 27%
Chemical synthesis and alkaloids
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Advanced Solid Phase Extraction Tools for Measuring Bempedoic Acid and its Active Metabolite in Human Plasma by Using LC-MS/MS — N. Devanna, Mahesh Meghavath · Indian Journal of Pharmaceutical Education and Research (2025) | TGRS Research Map | TGRS