Quality by Design (QbD) Based Development and Validation of RP-HPLC Method for Simultaneous Estimation of Metformin and Teneligliptin in Bulk and their Pharmaceutical Formulation

Aim: To develop and validate simple, accurate, precise, sensitive and robust Reversed Phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of metformin and teneligliptin in bulk and their pharmaceutical formulation by using Quality by Design (QbD) approach. Materials and Methods: The factor screening studies were performed using 2 level 4 factor (16 run) full factorial design. C18 Gracesmart column (150×4.6 mm, 5 μ) was saturated with mobile phase acetate buffer pH 4: acetonitrile (56.4: 43.6 v/v). Mobile phase was pumped at flow rate 1 mL/min. Both the drugs metformin and teneligliptin detected by diode array detector at wavelength 250 nm. Results: Retention time for metformin and teneligliptin were found to be 1.983 min and 3.263 min respectively. Metformin and teneligliptin show linear response in concentration range 50-300 μg/mL and 2-12 μg/mL respectively. % Recovery for metformin and teneligliptin was found to be 100.15%-101.43% and 98.76%-99.48% respectively. In precision study % relative standard deviation was found less than 2 for metformin and teneligliptin. Limit of Detection (LOD) for metformin and teneligliptin was found to be 1.281 μg/ mL and 0.464 μg/mL respectively. Limit of Quantification (LOQ) for metformin and teneligliptin was found to be 3.881 μg/mL and 1.407 μg/mL respectively. Conclusion: The proposed method was found to be accurate, precise, sensitive and robust. As a result, it might be successfully employed for the routine analysis of metformin and teneligliptin in bulk and their pharmaceutical dosage forms.

Authors

Institutions

Publication Details

Journal
Indian Journal of Pharmaceutical Education and Research
Published
2025-04-24
DOI
https://doi.org/10.5530/ijper.20253717
Citations
2
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
1.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality by Design (QbD) Based Development and Validation of RP-HPLC Method for Simultaneous Estimation of Metformin and Teneligliptin in Bulk and their Pharmaceutical Formulation

Kamlesh Jivani, Vashisth Bhavsar, J. Upadhyay, Shantilal Padhiyar et al.
2 citations
Indian Journal of Pharmaceutical Education and Research
Analytical Methods in Pharmaceuticals
1.50
article

Quality by Design (QbD) Based Development and Validation of RP-HPLC Method for Simultaneous Estimation of Metformin and Teneligliptin in Bulk and their Pharmaceutical Formulation

Kamlesh Jivani, Vashisth Bhavsar, J. Upadhyay, Shantilal Padhiyar, Tejas Patel, Vipul Prajapati
article en
2 citations

Abstract

Aim: To develop and validate simple, accurate, precise, sensitive and robust Reversed Phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of metformin and teneligliptin in bulk and their pharmaceutical formulation by using Quality by Design (QbD) approach. Materials and Methods: The factor screening studies were performed using 2 level 4 factor (16 run) full factorial design. C18 Gracesmart column (150×4.6 mm, 5 μ) was saturated with mobile phase acetate buffer pH 4: acetonitrile (56.4: 43.6 v/v). Mobile phase was pumped at flow rate 1 mL/min. Both the drugs metformin and teneligliptin detected by diode array detector at wavelength 250 nm. Results: Retention time for metformin and teneligliptin were found to be 1.983 min and 3.263 min respectively. Metformin and teneligliptin show linear response in concentration range 50-300 μg/mL and 2-12 μg/mL respectively. % Recovery for metformin and teneligliptin was found to be 100.15%-101.43% and 98.76%-99.48% respectively. In precision study % relative standard deviation was found less than 2 for metformin and teneligliptin. Limit of Detection (LOD) for metformin and teneligliptin was found to be 1.281 μg/ mL and 0.464 μg/mL respectively. Limit of Quantification (LOQ) for metformin and teneligliptin was found to be 3.881 μg/mL and 1.407 μg/mL respectively. Conclusion: The proposed method was found to be accurate, precise, sensitive and robust. As a result, it might be successfully employed for the routine analysis of metformin and teneligliptin in bulk and their pharmaceutical dosage forms.

Indian Journal of Pharmaceutical Education and ResearchVol. 59(2s)
Dharmsinh Desai University (IN), B.J. Medical College (IN)
Dharmsinh Desai University
Industry, innovation and infrastructure
Openalex Percentile: Top 20%
Analytical Methods in Pharmaceuticals
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.