CT Number Conformity Test on Multislice CT Scan at Yogyakarta PDHI Islamic Hospital

This research focuses on determining the CT number, which is the attenuation coefficient value of x-rays after passing through an organ. The level of energy attenuation depends on the initial energy of the x-rays and the atomic number of the object, which play a role in describing differences in the characteristics of organs or body tissues. This research aims to ensure the suitability of the CT number to obtain accurate information about CT scan images. Research procedures include observation, data collection, and data processing. The CT number data from the experimental results was then compared with the simulation results using IndoQCT software. The CT Number conformity test is carried out on a water phantom by adjusting the tube voltage, input current, and slice thickness. The Region of Interest (ROI) is made in the form of a circle at five measurement points, namely the central direction, 3 o'clock, 6 o'clock, 9 o'clock, and 12 o'clock. The research results, both direct testing and simulation using IndoQCT software, show that the CT number does not exceed the accuracy tolerance limit and uniformity, respectively, -4 ˂ HU ˂ +4 and -2 ˂ HU ˂ +2. Based on the analysis results, it can be concluded that the CT number measurements in the Radiology Unit at the Yogyakarta PDHI Islamic Hospital meet the requirements of BAPETEN Perka Number 2 of 2018.

Authors

Institutions

Publication Details

Journal
Sunan Kalijaga Journal of Physics
Published
2025-04-25
DOI
https://doi.org/10.14421/physics.v6i1.5140
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CT Number Conformity Test on Multislice CT Scan at Yogyakarta PDHI Islamic Hospital

Ali Roo'in Mas'uul
Sunan Kalijaga Journal of Physics
Radiomics and Machine Learning in Medical Imaging
article

CT Number Conformity Test on Multislice CT Scan at Yogyakarta PDHI Islamic Hospital

Ali Roo'in Mas'uul
article en

Abstract

This research focuses on determining the CT number, which is the attenuation coefficient value of x-rays after passing through an organ. The level of energy attenuation depends on the initial energy of the x-rays and the atomic number of the object, which play a role in describing differences in the characteristics of organs or body tissues. This research aims to ensure the suitability of the CT number to obtain accurate information about CT scan images. Research procedures include observation, data collection, and data processing. The CT number data from the experimental results was then compared with the simulation results using IndoQCT software. The CT Number conformity test is carried out on a water phantom by adjusting the tube voltage, input current, and slice thickness. The Region of Interest (ROI) is made in the form of a circle at five measurement points, namely the central direction, 3 o'clock, 6 o'clock, 9 o'clock, and 12 o'clock. The research results, both direct testing and simulation using IndoQCT software, show that the CT number does not exceed the accuracy tolerance limit and uniformity, respectively, -4 ˂ HU ˂ +4 and -2 ˂ HU ˂ +2. Based on the analysis results, it can be concluded that the CT number measurements in the Radiology Unit at the Yogyakarta PDHI Islamic Hospital meet the requirements of BAPETEN Perka Number 2 of 2018.

Sunan Kalijaga Journal of PhysicsVol. 6(1)
Rumah Sakit Umum Pusat Dr. Sardjito (ID)
Openalex Percentile: Top 87%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.