Enhanced Voltage Sensorless Control for a PWM Converter with DSOGI-FLL Under Grid Disturbances

This paper presents Enhanced Voltage Sensorless Control for PWM converter with DSOGI-FLL under grid disturbances. Even without grid voltage sensors, the proposed method accurately estimates the grid angle and voltage, which are necessary for power transfer between the DC link of the PWM converter and the grid. The estimated grid voltage obtained through observer design is separated into positive and negative sequence components, and the grid frequency is estimated using the Dual Second-Order Generalized Integrator Quadrature Signal Generator (DSOGI-QSG) and Dual Second-Order Generalized Integrator Frequency-Locked Loop (DSOGI-FLL). The estimated positive and negative sequence voltages were effectively controlled using a dual current controller. The method operates effectively under normal, balanced AC source conditions and in various grid fault scenarios, including unbalanced voltage, harmonic distortion, voltage sag, and frequency step changes. The validity of the proposed method was evaluated through experimental results by using a grid simulator to implement the fault condition.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-04-25
DOI
https://doi.org/10.3390/en18092199
Citations
1
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Voltage Sensorless Control for a PWM Converter with DSOGI-FLL Under Grid Disturbances

Dong-Youn Kim, Jang-Mok Kim, Sejin Kang
1 citations
Energies
Advanced DC-DC Converters
0.73
article

Enhanced Voltage Sensorless Control for a PWM Converter with DSOGI-FLL Under Grid Disturbances

Dong-Youn Kim, Jang-Mok Kim, Sejin Kang
article en
1 citations

Abstract

This paper presents Enhanced Voltage Sensorless Control for PWM converter with DSOGI-FLL under grid disturbances. Even without grid voltage sensors, the proposed method accurately estimates the grid angle and voltage, which are necessary for power transfer between the DC link of the PWM converter and the grid. The estimated grid voltage obtained through observer design is separated into positive and negative sequence components, and the grid frequency is estimated using the Dual Second-Order Generalized Integrator Quadrature Signal Generator (DSOGI-QSG) and Dual Second-Order Generalized Integrator Frequency-Locked Loop (DSOGI-FLL). The estimated positive and negative sequence voltages were effectively controlled using a dual current controller. The method operates effectively under normal, balanced AC source conditions and in various grid fault scenarios, including unbalanced voltage, harmonic distortion, voltage sag, and frequency step changes. The validity of the proposed method was evaluated through experimental results by using a grid simulator to implement the fault condition.

EnergiesVol. 18(9)
Pusan National University (KR)
Ministry of Trade, Industry and Energy
Openalex Percentile: Top 29%
Advanced DC-DC Converters
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.