Fluorescence Intensity Response of Fumed Silica Films with Immobilized 7-hydroxy-4-methylcoumarin to Acetone Microconcentrations in Air

The spectral-fluorescence properties of the 7-hydroxy-4-methylcoumarin (Cou4) dye dissolved in ethanol and immobilized in the fumed silica (A-380 aerosil) sorbent in the form of films and their changes upon interaction with acetone molecules have been investigated. The dependence of the change in fluorescence intensity of such film samples on the concentrations of acetone and ethanol in the air in the 3–15 ppm range has been determined. The obtained results indicate the possibility of using the films for the sensory determination of acetone in the air selectively to simple alcohols (ethanol), particularly, for non-invasive diagnosis of diabetes by analyzing the exhaled human air.

Authors

Publication Details

Journal
Ukrainian Journal of Physics
Published
2025-04-25
DOI
https://doi.org/10.15407/ujpe70.4.237
Primary Topic
Mesoporous Materials and Catalysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluorescence Intensity Response of Fumed Silica Films with Immobilized 7-hydroxy-4-methylcoumarin to Acetone Microconcentrations in Air

С. А. Мамилов, V. O. Sokolov, Ya. P. Lazorenko, S. V. Kryvets
Ukrainian Journal of Physics
Mesoporous Materials and Catalysis
article

Fluorescence Intensity Response of Fumed Silica Films with Immobilized 7-hydroxy-4-methylcoumarin to Acetone Microconcentrations in Air

С. А. Мамилов, V. O. Sokolov, Ya. P. Lazorenko, S. V. Kryvets
article en

Abstract

The spectral-fluorescence properties of the 7-hydroxy-4-methylcoumarin (Cou4) dye dissolved in ethanol and immobilized in the fumed silica (A-380 aerosil) sorbent in the form of films and their changes upon interaction with acetone molecules have been investigated. The dependence of the change in fluorescence intensity of such film samples on the concentrations of acetone and ethanol in the air in the 3–15 ppm range has been determined. The obtained results indicate the possibility of using the films for the sensory determination of acetone in the air selectively to simple alcohols (ethanol), particularly, for non-invasive diagnosis of diabetes by analyzing the exhaled human air.

Ukrainian Journal of PhysicsVol. 70(4)
Openalex Percentile: Top 94%
Mesoporous Materials and Catalysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.