Optimizing the Anatomical Location and Procedural Parameters for Miniscrew Placement in the Infrazygomatic Region- A CBCT Study

This study evaluates the integration of anatomical and procedural guidelines to develop realistic protocols for successful miniscrew insertion in the infrazygomatic crest (IZC) region, using CBCT measurements. A total of 720 measurements were collected from 30 adult patients, focusing on the upper first molar (U6) region. A grid system was created in the sagittal plane, including 12 reference points around the U6, with horizontal and vertical measurement points. A 12-mm virtual IZC miniscrew was inserted at each reference point, with the angle adjusted for 1 mm of sinus penetration and 5 mm of projection beyond the bone surface. Insertion success was defined as maintaining a minimum 0.5 mm safe distance from the roots, classified as system-compatible (SC), while root contact (RC), failure to achieve sinus penetration (SF), or sinus perforation (SP) exceeding 1 mm were classified as failures. No significant differences were found among the reference regions (p > 0.05). The 15 mm-U6MB region, with an insertion angle of 41.22°±8.67° apically and 12.36°±2.48° mesially, had the highest success rate of 55.0 %. The 15 mm-U6DB region, while aligning with the guidelines, had a higher incidence of root proximity (56.9 %). At the 17 mm region, sinus perforations exceeded 1 mm in 96.8 % of cases. The recommended placement height of 15 mm above the POP, with a 40° apical and 10° mesial angle at U6MB, offers the best balance of stability and safety, in line with literature guidelines. This study provides clinicians with evidence for effective miniscrew placement, ensuring stability while avoiding critical anatomical structures.

Authors

Institutions

Publication Details

Journal
Journal of Stomatology Oral and Maxillofacial Surgery
Published
2025-04-25
DOI
https://doi.org/10.1016/j.jormas.2025.102390
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing the Anatomical Location and Procedural Parameters for Miniscrew Placement in the Infrazygomatic Region- A CBCT Study

Salih Altun, Tuğba Haliloğlu Özkan, B. Yilmaz
Journal of Stomatology Oral and Maxillofacial Surgery
Orthodontics and Dentofacial Orthopedics
article

Optimizing the Anatomical Location and Procedural Parameters for Miniscrew Placement in the Infrazygomatic Region- A CBCT Study

Salih Altun, Tuğba Haliloğlu Özkan, B. Yilmaz
article en

Abstract

This study evaluates the integration of anatomical and procedural guidelines to develop realistic protocols for successful miniscrew insertion in the infrazygomatic crest (IZC) region, using CBCT measurements. A total of 720 measurements were collected from 30 adult patients, focusing on the upper first molar (U6) region. A grid system was created in the sagittal plane, including 12 reference points around the U6, with horizontal and vertical measurement points. A 12-mm virtual IZC miniscrew was inserted at each reference point, with the angle adjusted for 1 mm of sinus penetration and 5 mm of projection beyond the bone surface. Insertion success was defined as maintaining a minimum 0.5 mm safe distance from the roots, classified as system-compatible (SC), while root contact (RC), failure to achieve sinus penetration (SF), or sinus perforation (SP) exceeding 1 mm were classified as failures. No significant differences were found among the reference regions (p > 0.05). The 15 mm-U6MB region, with an insertion angle of 41.22°±8.67° apically and 12.36°±2.48° mesially, had the highest success rate of 55.0 %. The 15 mm-U6DB region, while aligning with the guidelines, had a higher incidence of root proximity (56.9 %). At the 17 mm region, sinus perforations exceeded 1 mm in 96.8 % of cases. The recommended placement height of 15 mm above the POP, with a 40° apical and 10° mesial angle at U6MB, offers the best balance of stability and safety, in line with literature guidelines. This study provides clinicians with evidence for effective miniscrew placement, ensuring stability while avoiding critical anatomical structures.

Journal of Stomatology Oral and Maxillofacial SurgeryVol. 126(4)
Sağlık Bilimleri Üniversitesi (TR), Istanbul Medeniyet University (TR), University of Health Sciences Antigua (AG)
Openalex Percentile: Top 91%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.