Novel Hybrid Algorithm for Investigation of Dissolved Gas Analysis for Alternate Dielectric Fluids of Power Transformer

The power transformer is the most important element of equipment in an electrical transmission and distribution network. The power and voltage levels that these transformers can manage determine their size, and as the transformer's volume increases, internal isolation and cooling become more challenging. The most popular insulating fluid used in transformers for insulation and cooling is mineral-based oil, which has demonstrated exceptional dielectric and thermal qualities. However, alternative oil technologies have been sought to replace mineral-based oils in recent years because to concerns about safety, cost, and environmental impact. In this context, extensive research efforts have emerged on biological oils for use in transformers. This paper examines the sustainability, safety, and electrical performance of bio-based ester oil in transformer applications with respect to dissolved gas analysis (DGA). AI-based Fuzzy logic controller (FLC) with Duval's triangle (DT) and Duval's pentagon (DP), IEC, CIGRE reports are used in a hybrid manner to identify the possible incipient faults inside the oil-immersed transformers. The graphical analysis of various fuzzy logic plots along with DT and DP are utilized to critically analyze the possible incipient faults arrayed due to DGA. The proposed work proficient compared to previously published results. Highest efficiency of DT and DP based FLC (92%), followed by furan analysis (82.3%). Lastly, recommendations are made on potential fixes for the problems raised and the future course of study for alternate dielectric fluids-based power transformers. The suggested techniques in this research offer a higher diagnostic accuracy than the present approach.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/ssdee64538.2025.10968045
Citations
1
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Hybrid Algorithm for Investigation of Dissolved Gas Analysis for Alternate Dielectric Fluids of Power Transformer

Norazhar Abu Bakar, Raymon Antony Raj, Mohamed M. F. Darwish, Bishal Silwal et al.
1 citations
Power Transformer Diagnostics and Insulation
0.73
article

Novel Hybrid Algorithm for Investigation of Dissolved Gas Analysis for Alternate Dielectric Fluids of Power Transformer

Norazhar Abu Bakar, Raymon Antony Raj, Mohamed M. F. Darwish, Bishal Silwal, Rahman Azis Prasojo, Rahul Soni
article en
1 citations

Abstract

The power transformer is the most important element of equipment in an electrical transmission and distribution network. The power and voltage levels that these transformers can manage determine their size, and as the transformer's volume increases, internal isolation and cooling become more challenging. The most popular insulating fluid used in transformers for insulation and cooling is mineral-based oil, which has demonstrated exceptional dielectric and thermal qualities. However, alternative oil technologies have been sought to replace mineral-based oils in recent years because to concerns about safety, cost, and environmental impact. In this context, extensive research efforts have emerged on biological oils for use in transformers. This paper examines the sustainability, safety, and electrical performance of bio-based ester oil in transformer applications with respect to dissolved gas analysis (DGA). AI-based Fuzzy logic controller (FLC) with Duval's triangle (DT) and Duval's pentagon (DP), IEC, CIGRE reports are used in a hybrid manner to identify the possible incipient faults inside the oil-immersed transformers. The graphical analysis of various fuzzy logic plots along with DT and DP are utilized to critically analyze the possible incipient faults arrayed due to DGA. The proposed work proficient compared to previously published results. Highest efficiency of DT and DP based FLC (92%), followed by furan analysis (82.3%). Lastly, recommendations are made on potential fixes for the problems raised and the future course of study for alternate dielectric fluids-based power transformers. The suggested techniques in this research offer a higher diagnostic accuracy than the present approach.

State University of Malang (ID), Tribhuvan University (NP), Universiti Teknologi Petronas (MY), Benha University (EG), Institute of Engineering (NP)
Openalex Percentile: Top 29%
Power Transformer Diagnostics and Insulation
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.