Evaluation of High Resistance Grounding in Medium Voltage Marine Systems

Grounding schemes play a significant role in maintaining the safety and operational efficiency onboard ships. The widely preferred grounding scheme is the floating neutral system due to the advantage of continual operation despite a fault in any of the phases. However, the transient voltages during the fault may result in multi-phase faults and eventually damage the complete system. The High Resistance Grounding (HRG) scheme resolves this problem while retaining all the benefits of an ungrounded system. The complexity in implementing the HRG scheme lies in choosing a resistor whose magnitude is less than the charging capacitance of the system. As per IEEE 45.4 −2018, the HRG scheme is recommended for LV systems only. To extend the benefits of HRG to MV systems, a comprehensive analysis with real-time data is necessary. In this paper, the performance of the HRG system for MV ship systems is evaluated, considering the specific challenges and design considerations unique to MV systems. The results of the HRG system are found satisfactory as the transients are not reflected when a high impedance fault is created.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/ssdee64538.2025.10967842
Primary Topic
Maritime Transport Emissions and Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of High Resistance Grounding in Medium Voltage Marine Systems

Shashidhar Kasthala, Nithya Chandran, Naveen Kumar, G. Radhika
Maritime Transport Emissions and Efficiency
article

Evaluation of High Resistance Grounding in Medium Voltage Marine Systems

Shashidhar Kasthala, Nithya Chandran, Naveen Kumar, G. Radhika
article en

Abstract

Grounding schemes play a significant role in maintaining the safety and operational efficiency onboard ships. The widely preferred grounding scheme is the floating neutral system due to the advantage of continual operation despite a fault in any of the phases. However, the transient voltages during the fault may result in multi-phase faults and eventually damage the complete system. The High Resistance Grounding (HRG) scheme resolves this problem while retaining all the benefits of an ungrounded system. The complexity in implementing the HRG scheme lies in choosing a resistor whose magnitude is less than the charging capacitance of the system. As per IEEE 45.4 −2018, the HRG scheme is recommended for LV systems only. To extend the benefits of HRG to MV systems, a comprehensive analysis with real-time data is necessary. In this paper, the performance of the HRG system for MV ship systems is evaluated, considering the specific challenges and design considerations unique to MV systems. The results of the HRG system are found satisfactory as the transients are not reflected when a high impedance fault is created.

Naval Academy (TR)
Life below water
Openalex Percentile: Top 92%
Maritime Transport Emissions and Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.