Analysis of VSC-HVDC System in the Asynchronously Operating Grids During AC Line Faults

The growing energy demand and ruler electrification accelerates the integration of synchronously and asynchronously operating grids. Generation based on hydro, wind or solar may operate at a frequency slightly different than the national grid due to its intermittent nature and operational constraints. It is important to integrate the generation of various sources to improve grid reliability. Wind energy farms are usually integrated into the grid using VSC (voltage source converters)-HVDC systems. Faults on either side of the HVDC link may create operational and stability issues for interconnecting the HVDC link. The fault ride-through is the ability of the VSC-HVDC system to remain connected with the grid during faults. This paper explores and analyzes the fault ride-through ability of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{a}\pm \mathbf{100}\ \mathbf{kV}$</tex>, 200 MW two-level VSC-HVDC to maintain interconnections between grids, especially during the presence of intermittent sources like wind farms at one end of the VSC-HVDC system.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/ssdee64538.2025.10968488
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of VSC-HVDC System in the Asynchronously Operating Grids During AC Line Faults

Ravi Shankar Tiwari, Prashant Kumar, Ashish Kumar Sinha
1 citations
HVDC Systems and Fault Protection
0.73
article

Analysis of VSC-HVDC System in the Asynchronously Operating Grids During AC Line Faults

Ravi Shankar Tiwari, Prashant Kumar, Ashish Kumar Sinha
article en
1 citations

Abstract

The growing energy demand and ruler electrification accelerates the integration of synchronously and asynchronously operating grids. Generation based on hydro, wind or solar may operate at a frequency slightly different than the national grid due to its intermittent nature and operational constraints. It is important to integrate the generation of various sources to improve grid reliability. Wind energy farms are usually integrated into the grid using VSC (voltage source converters)-HVDC systems. Faults on either side of the HVDC link may create operational and stability issues for interconnecting the HVDC link. The fault ride-through is the ability of the VSC-HVDC system to remain connected with the grid during faults. This paper explores and analyzes the fault ride-through ability of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{a}\pm \mathbf{100}\ \mathbf{kV}$</tex>, 200 MW two-level VSC-HVDC to maintain interconnections between grids, especially during the presence of intermittent sources like wind farms at one end of the VSC-HVDC system.

Dongguk University (KR), GLA University (IN)
Affordable and clean energy
Openalex Percentile: Top 29%
HVDC Systems and Fault Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.