Condition Assessment of Dielectric Liquid Used in Large Power Equipment Using Time-Varying Model

This paper presents a non-invasive approach for assessing the condition of dielectric liquids, particularly mineral oils, used in power transformers by employing a Time-Varying Model (TVM) to analyze polarization current profiles. Ageing in dielectric liquids can compromise transformer reliability. Hence, effective monitoring is essential. In this study, mineral oil samples are subjected to accelerated ageing, with polarization current measurements analyzed via TVM. Performance parameters, including conductivity, dissipation factor, and relative permittivity, are evaluated using variance analysis to reveal more distinct ageing trends compared to traditional standard deviation methods. Findings suggest that variance analysis provides a more accurate depiction of oil degradation, supporting condition-based maintenance and reducing transformer failure risks.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/ssdee64538.2025.10968128
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Condition Assessment of Dielectric Liquid Used in Large Power Equipment Using Time-Varying Model

Arijit Baral, Praveen Kumar, Somesh Ganguly, Vikash Kumar Raushan
Engineering Applied Research
article

Condition Assessment of Dielectric Liquid Used in Large Power Equipment Using Time-Varying Model

Arijit Baral, Praveen Kumar, Somesh Ganguly, Vikash Kumar Raushan
article en

Abstract

This paper presents a non-invasive approach for assessing the condition of dielectric liquids, particularly mineral oils, used in power transformers by employing a Time-Varying Model (TVM) to analyze polarization current profiles. Ageing in dielectric liquids can compromise transformer reliability. Hence, effective monitoring is essential. In this study, mineral oil samples are subjected to accelerated ageing, with polarization current measurements analyzed via TVM. Performance parameters, including conductivity, dissipation factor, and relative permittivity, are evaluated using variance analysis to reveal more distinct ageing trends compared to traditional standard deviation methods. Findings suggest that variance analysis provides a more accurate depiction of oil degradation, supporting condition-based maintenance and reducing transformer failure risks.

Indian Institute of Technology Dhanbad (IN)
Affordable and clean energy
Openalex Percentile: Top 91%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines