A New Method to Detect DMR Faults During Balanced Condition for a VSC Bipole Onshore-Offshore HVDC Network

The bipole High-Voltage Direct Current (HVDC) systems can transmit high power rating when compared with monopole HVDC link. The flexibility and reliability that is provided by the bipole configuration make it an attractive solution for power transmission from offshore wind farms to onshore grid. These bipole HVDCs have dedicated metallic return (DMR) as a return path and ground references. The detection of fault in the DMR cable of a bipole HVDC is a challenging task. Traditional over-current and differential protection fail to detect the faults in the network. In this paper, the moving window-based Pearson correlation coefficient (MWPCC), variational mode decomposition (VMD) and bagging ensemble classifier (BEC) based two fault detection algorithms are proposed. The first two advanced signal processing methods are utilized to extract data for the classifier. The effectiveness of the proposed detection technique is demonstrated by applying different fault scenarios. The time domain simulations are performed using a full-scale industrial model, and the fault detection algorithms have achieved very high accuracy to detect the fault.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/ssdee64538.2025.10967813
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Method to Detect DMR Faults During Balanced Condition for a VSC Bipole Onshore-Offshore HVDC Network

Sauvik Biswas, Saikat Majumdar, Sunil Joshi, Omar Jasim et al.
HVDC Systems and Fault Protection
article

A New Method to Detect DMR Faults During Balanced Condition for a VSC Bipole Onshore-Offshore HVDC Network

Sauvik Biswas, Saikat Majumdar, Sunil Joshi, Omar Jasim, Kiran Kumar Math
article en

Abstract

The bipole High-Voltage Direct Current (HVDC) systems can transmit high power rating when compared with monopole HVDC link. The flexibility and reliability that is provided by the bipole configuration make it an attractive solution for power transmission from offshore wind farms to onshore grid. These bipole HVDCs have dedicated metallic return (DMR) as a return path and ground references. The detection of fault in the DMR cable of a bipole HVDC is a challenging task. Traditional over-current and differential protection fail to detect the faults in the network. In this paper, the moving window-based Pearson correlation coefficient (MWPCC), variational mode decomposition (VMD) and bagging ensemble classifier (BEC) based two fault detection algorithms are proposed. The first two advanced signal processing methods are utilized to extract data for the classifier. The effectiveness of the proposed detection technique is demonstrated by applying different fault scenarios. The time domain simulations are performed using a full-scale industrial model, and the fault detection algorithms have achieved very high accuracy to detect the fault.

Teledyne e2v (United Kingdom) (GB)
Climate action
Openalex Percentile: Top 93%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.