PV Array Fault Detection and Location Estimation Using Ensemble Learning Model

Currently, large-scale grid connected solar power plants are being installed in MW range for electricity generation. The PV arrays of these large-scale solar power plants are exposed to different electrical faults. The misdetection of faults can create problems in effective operation of solar power plant and can also lead to fire hazards. The magnitude of fault current depends on the irradiance level as well as number of modules getting affected. Consequently, the change in the magnitude of fault currents especially during high impedance ground faults and low mismatch faults is insignificant. The fixed fuse rating of conventional protection schemes like overcurrent protection devices and ground fault detection interrupters have limitations in detection of such crucial faults. In this paper, an ensemble learning model-based technique is used for detection of faults and faulted strings in PV arrays using string current and array voltage simulated through MATLAB/Simulink. The effectiveness of the proposed method is validated and demonstrated through simulated results.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/ssdee64538.2025.10968531
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PV Array Fault Detection and Location Estimation Using Ensemble Learning Model

Subodh Kumar Mohanty, Paresh Kumar Nayak, Shubham Kumar
Photovoltaic System Optimization Techniques
article

PV Array Fault Detection and Location Estimation Using Ensemble Learning Model

Subodh Kumar Mohanty, Paresh Kumar Nayak, Shubham Kumar
article en

Abstract

Currently, large-scale grid connected solar power plants are being installed in MW range for electricity generation. The PV arrays of these large-scale solar power plants are exposed to different electrical faults. The misdetection of faults can create problems in effective operation of solar power plant and can also lead to fire hazards. The magnitude of fault current depends on the irradiance level as well as number of modules getting affected. Consequently, the change in the magnitude of fault currents especially during high impedance ground faults and low mismatch faults is insignificant. The fixed fuse rating of conventional protection schemes like overcurrent protection devices and ground fault detection interrupters have limitations in detection of such crucial faults. In this paper, an ensemble learning model-based technique is used for detection of faults and faulted strings in PV arrays using string current and array voltage simulated through MATLAB/Simulink. The effectiveness of the proposed method is validated and demonstrated through simulated results.

Indian Institute of Technology Dhanbad (IN), KIIT University (IN)
Climate action
Openalex Percentile: Top 95%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PV Array Fault Detection and Location Estimation Using Ensemble Learning Model — Subodh Kumar Mohanty, Paresh Kumar Nayak, et al. · (2025) | TGRS Research Map | TGRS