Bismuth Functionalized Inkjet-Printed Electrochemical Sensor for Aqueous Lead (II) Detection

This article introduces a sensitive, selective, and reusable 3D bismuth functionalized inkjet printed shape memory polymer incorporated electrochemical sensor (ECS) for detecting lead (II) in aqueous solution i.e., deionized water, tap water, and river water. The reported ECS comprises a bismuth deposited working electrode (WE), a gold (Au) counter electrode, and a silver chloride reference electrode. Bismuth functionalization was performed through two approaches on the inkjet printed Au plated (thickness – 8.24 μm±1.42) electrodes: ex situ, involving a full cycle of cyclic voltammetry (CV) process to deposit bismuth – 400 μg/L bismuth, and in situ, where CV or square wave anodic stripping voltammetry were performed with a lead (II) contaminated aqueous solution diluted with 200 μg/L bismuth. The limit of detection for the bismuth functionalized inkjet printed ECSs are 0.64 μg/dL (ex situ) for the bismuth deposited WE (13.92 Ω.□±1.96) and 1.09 μg/dL (in situ) for the Au WE (4.4 Ω.□±0.3). The sensor, designed for miniaturization, exhibits enhanced performance in electrochemical sensing due to its increased effective electrode surface area (7.25 mm2±0.15) despite a reduced lateral surface area (4.19 mm2). An optimized cleaning process and a mathematical model representing the relationship between printed and electrical areas of the inkjet printed electrodes are presented thoroughly to provide flexibility and certainty of designing different electrochemical and biosensors. Conclusively, the design, fabrication, bismuth functionalization, characterization, and optimization encompassing sensitivity, selectivity, reproducibility, reusability, and cost-assessment of the bismuth functionalized inkjet printed ECS for aqueous lead (II) detection are delineated in this article in detail.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-25
DOI
https://doi.org/10.1109/jsen.2025.3562804
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bismuth Functionalized Inkjet-Printed Electrochemical Sensor for Aqueous Lead (II) Detection

Annatoma Arif, Carlos R. Cabrera, Alexis J. Acevedo-González, Robert C. Roberts
IEEE Sensors Journal
Electrochemical Analysis and Applications
article

Bismuth Functionalized Inkjet-Printed Electrochemical Sensor for Aqueous Lead (II) Detection

Annatoma Arif, Carlos R. Cabrera, Alexis J. Acevedo-González, Robert C. Roberts
article en

Abstract

This article introduces a sensitive, selective, and reusable 3D bismuth functionalized inkjet printed shape memory polymer incorporated electrochemical sensor (ECS) for detecting lead (II) in aqueous solution i.e., deionized water, tap water, and river water. The reported ECS comprises a bismuth deposited working electrode (WE), a gold (Au) counter electrode, and a silver chloride reference electrode. Bismuth functionalization was performed through two approaches on the inkjet printed Au plated (thickness – 8.24 μm±1.42) electrodes: ex situ, involving a full cycle of cyclic voltammetry (CV) process to deposit bismuth – 400 μg/L bismuth, and in situ, where CV or square wave anodic stripping voltammetry were performed with a lead (II) contaminated aqueous solution diluted with 200 μg/L bismuth. The limit of detection for the bismuth functionalized inkjet printed ECSs are 0.64 μg/dL (ex situ) for the bismuth deposited WE (13.92 Ω.□±1.96) and 1.09 μg/dL (in situ) for the Au WE (4.4 Ω.□±0.3). The sensor, designed for miniaturization, exhibits enhanced performance in electrochemical sensing due to its increased effective electrode surface area (7.25 mm2±0.15) despite a reduced lateral surface area (4.19 mm2). An optimized cleaning process and a mathematical model representing the relationship between printed and electrical areas of the inkjet printed electrodes are presented thoroughly to provide flexibility and certainty of designing different electrochemical and biosensors. Conclusively, the design, fabrication, bismuth functionalization, characterization, and optimization encompassing sensitivity, selectivity, reproducibility, reusability, and cost-assessment of the bismuth functionalized inkjet printed ECS for aqueous lead (II) detection are delineated in this article in detail.

IEEE Sensors JournalVol. 25(11)
The University of Texas at El Paso (US), University of Puerto Rico at Río Piedras (PR), National Postdoctoral Association (US), Stanford University (US)
National Science Foundation
Openalex Percentile: Top 91%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.