Equal image quality and reduced radiation exposure in whole-spine X-ray imaging with slot-scanning technique compared with stitched radiography
Repeated whole-spine imaging in children and adolescents with scoliosis causes significant cumulative radiation exposure. Low-dose slot-scanning imaging can reduce radiation exposure. The aim of this study was to compare whole-spine imaging using the slot-scanning technique (SST) with conventional stitched radiography (SR) with regard to image quality and radiation dose.We recruited 30 patients with a clinical indication for whole-spine imaging by SST, who had prior whole-spine imaging by SR available. 41 images acquired using both techniques were analyzed. The dose area product (DAP) and patient age, weight, height, and body-mass index were recorded. Image quality was assessed for 28 anatomical landmarks on a 4-point Likert scale by 4 raters. Group-wise comparisons were performed using paired t-tests. Interrater rating reliability was assessed using the interrater correlation coefficient.The mean DAP was significantly lower for SST than for SR (SST 8.0 ± 5.7 cGy · cm², SR 32.5 ± 34.5 cGy · cm², p < 0.001). The image quality was rated good for both modalities (means: SST 2.8 ± 0.6, SR 2.7 ± 0.5, p = 0.38). There was no significant difference in image quality ratings between both modalities. The inter-rater reliability was excellent with an inter-rater correlation coefficient of 0.86. Orthopedic surgeons rated the image quality of SST significantly better than that of SR.This study shows a significant reduction in radiation exposure for slot-scanning whole-spine imaging compared to stitched radiography with equal image quality, which facilitates the reduction of radiation exposure for repeated whole-spine imaging in children and adolescents to 25%. · Image quality is comparable between slot-scanning and stitched whole-spine imaging.. · The slot-scanning technique had a significantly lower dose area product compared with stitched radiographs.. · Orthopedic surgeons rated the image quality of slot-scanning significantly better than that of stitching.. · Radiation exposure in scoliosis whole-spine imaging can be reduced to 25%.. · Liebscher H, Scherzer M, Meißner C et al. Equal image quality and reduced radiation exposure in whole-spine X-ray imaging with slot-scanning technique compared with stitched radiography. Rofo 2026; 198: 219-227.
Authors
- Patricia Hahlbohm
- Sophia F. U. Blum (ORCID: https://orcid.org/0000-0001-7096-5199)
- Mechthild Scherzer
- Christoph Meißner
- Ralf‐Thorsten Hoffmann (ORCID: https://orcid.org/0000-0003-3150-4263)
- Hendrik Liebscher
- Stefan Zwingenberger (ORCID: https://orcid.org/0000-0002-1831-3035)
- Jens‐Peter Kühn (ORCID: https://orcid.org/0000-0003-3258-930X)
- Felix Schön (ORCID: https://orcid.org/0000-0003-4377-2345)
- Uwe Platz
Institutions
- University Hospital Carl Gustav Carus (DE)
- Technische Universität Dresden (DE)
Publication Details
- Journal
- RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Published
- 2025-04-25
- DOI
- https://doi.org/10.1055/a-2564-0580
- Primary Topic
- Scoliosis diagnosis and treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Siemens Healthineers