Rapid diagnosis of diquat and paraquat poisoning: A dual approach using colloidal gold immunochromatographic assay and hydrophilic interaction liquid chromatography

Accurate diagnosis and treatment in poisoning cases necessitate the monitoring of diquat and paraquat concentrations. This study presents a competitive colloidal gold immunochromatographic assay (GICA) strip for qualitative detection, alongside hydrophilic interaction liquid chromatography with ultraviolet detection (HILIC-UV) for quantitative assessment. Both methods underwent rigorous validation. The GICA strip achieved a detection limit of 20 ng/mL and demonstrated no cross-reactivity with glyphosate, deltamethrin, or dichlorvos in spiked serum samples. A compliance rate of 100 % confirmed its repeatability, validated by ten quality control samples at a concentration of 200 ng/mL. HILIC-UV exhibited a detection limit of 0.2 μg/mL and excellent linearity for paraquat and diquat in serum and urine across a range of 0.2-6.4 μg/mL (r² > 0.99). Accuracy ranged from 86.4 % to 111.4 %, with relative standard deviation (RSD) below 10.8 %. Sigma metrics for quality control samples varied from 4.47 to 6.09, establishing a 1-3 s/2/3-2 s/R-4s internal quality control scheme (n = 3, r = 1). A total of 24 patient specimens were subjected to dual testing with HILIC-UV and GICA strips. Among these, 21 samples from 17 patients tested positive, while three patients with confirmed glyphosate, deltamethrin, and dichlorvos poisoning tested negative, indicating complete consistency. Of the positive results, 11 patients were diagnosed with paraquat poisoning, and six with diquat poisoning, both of which significantly impair liver, kidney, and coagulation functions. Integrating GICA for rapid qualitative assessment with HILIC-UV for quantitative analysis enhances the identification of diquat and paraquat poisoning, making it particularly suitable for emergency diagnostics.

Authors

Institutions

Publication Details

Journal
Journal of Pharmaceutical and Biomedical Analysis
Published
2025-04-25
DOI
https://doi.org/10.1016/j.jpba.2025.116923
Citations
4
Primary Topic
Paraquat toxicity studies and treatments
Type
article
Field-Weighted Citation Impact
8.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid diagnosis of diquat and paraquat poisoning: A dual approach using colloidal gold immunochromatographic assay and hydrophilic interaction liquid chromatography

Dongmei Tian, Xinxin Huang, Jiahui He, Teng Zhang et al.
4 citations
Journal of Pharmaceutical and Biomedical Analysis
Paraquat toxicity studies and treatments
8.03
article

Rapid diagnosis of diquat and paraquat poisoning: A dual approach using colloidal gold immunochromatographic assay and hydrophilic interaction liquid chromatography

Dongmei Tian, Xinxin Huang, Jiahui He, Teng Zhang, Ge Li, Ying Liu, Shuai Song, Quan Xia, Gang Han
article en
4 citations

Abstract

Accurate diagnosis and treatment in poisoning cases necessitate the monitoring of diquat and paraquat concentrations. This study presents a competitive colloidal gold immunochromatographic assay (GICA) strip for qualitative detection, alongside hydrophilic interaction liquid chromatography with ultraviolet detection (HILIC-UV) for quantitative assessment. Both methods underwent rigorous validation. The GICA strip achieved a detection limit of 20 ng/mL and demonstrated no cross-reactivity with glyphosate, deltamethrin, or dichlorvos in spiked serum samples. A compliance rate of 100 % confirmed its repeatability, validated by ten quality control samples at a concentration of 200 ng/mL. HILIC-UV exhibited a detection limit of 0.2 μg/mL and excellent linearity for paraquat and diquat in serum and urine across a range of 0.2-6.4 μg/mL (r² > 0.99). Accuracy ranged from 86.4 % to 111.4 %, with relative standard deviation (RSD) below 10.8 %. Sigma metrics for quality control samples varied from 4.47 to 6.09, establishing a 1-3 s/2/3-2 s/R-4s internal quality control scheme (n = 3, r = 1). A total of 24 patient specimens were subjected to dual testing with HILIC-UV and GICA strips. Among these, 21 samples from 17 patients tested positive, while three patients with confirmed glyphosate, deltamethrin, and dichlorvos poisoning tested negative, indicating complete consistency. Of the positive results, 11 patients were diagnosed with paraquat poisoning, and six with diquat poisoning, both of which significantly impair liver, kidney, and coagulation functions. Integrating GICA for rapid qualitative assessment with HILIC-UV for quantitative analysis enhances the identification of diquat and paraquat poisoning, making it particularly suitable for emergency diagnostics.

Journal of Pharmaceutical and Biomedical AnalysisVol. 263
Anhui Medical University (CN), Anhui University of Traditional Chinese Medicine (CN), Anhui Provincial Hospital (CN), First Affiliated Hospital of Anhui Medical University (CN)
Openalex Percentile: Top 3%
Paraquat toxicity studies and treatments
8.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.