Study of heat and moisture transfer processes in ventilation corridors of underground plants

For the ventilation corridors connecting underground plants and the outside atmosphere environment, the variation of corridor inner air parameters is an important factor for designing HVAC system of underground plants. This paper focuses on the boundary characteristics of ventilation corridors in an underground pumped storage power station. Utilizing the principles of heat and mass exchange, a mathematical model for the temperature and humidity distribution along unlined ventilation corridors has been established. Taking the ventilation passageway of a pumped storage power station in Shandong as the research object, the on-site air parameters measurement results under summer condition were compared with the theoretical calculations of the model. Results showed that the relative error between the two methods was within 10%. It can be deduced that the calculated results of the theoretical model can provide theoretical support for energy-saving in the HVAC systems of practical engineering.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1117/12.3062373
Primary Topic
Mining and Gasification Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of heat and moisture transfer processes in ventilation corridors of underground plants

Yong Liu, Tong Zhao, Hai Zhao, Wei Tian et al.
Mining and Gasification Technologies
article

Study of heat and moisture transfer processes in ventilation corridors of underground plants

Yong Liu, Tong Zhao, Hai Zhao, Wei Tian, Cun Liu, Qing Yang
article en

Abstract

For the ventilation corridors connecting underground plants and the outside atmosphere environment, the variation of corridor inner air parameters is an important factor for designing HVAC system of underground plants. This paper focuses on the boundary characteristics of ventilation corridors in an underground pumped storage power station. Utilizing the principles of heat and mass exchange, a mathematical model for the temperature and humidity distribution along unlined ventilation corridors has been established. Taking the ventilation passageway of a pumped storage power station in Shandong as the research object, the on-site air parameters measurement results under summer condition were compared with the theoretical calculations of the model. Results showed that the relative error between the two methods was within 10%. It can be deduced that the calculated results of the theoretical model can provide theoretical support for energy-saving in the HVAC systems of practical engineering.

Beijing University of Technology (CN), Midea Group (China) (CN), Beijing Founder Electronics (China) (CN)
Openalex Percentile: Top 92%
Mining and Gasification Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.