An Integrated Nanosensor/Smartphone Platform for Point-of-Care Biomonitoring of Human Exposure to Pesticides
Organophosphorus (OP) compounds are neurotoxins that are among the most widely used pesticides in agriculture in the United States. In this application, a new integrated point-of-care smartphone/resistive nanosensor device is developed for onsite rapid and sensitive detection of exposure to OP pesticides from a drop of finger-stick blood among a sample of farmworkers. The nanosensor leverages the transport properties of a multiwalled carbon nanotube/polyaniline nanofiber (MWCNT/PAnNF) nanocomposite film on a gold interdigitated electrode and acetylcholinesterase/butyrylcholinesterase (AChE/BChE) hydrolysis of their respective substrates generating protons doping PAnNFs, thereby increasing the conductance of the film. As such, a conductance change can be used to quantify cholinesterase activity, enabling assessment of acute/chronic OP poisoning. Additionally, a mobile app was developed for the nanosensor to process, display, track, and share results. Under optimal conditions, the nanosensor demonstrated exceptional sensitivity with the detection limits of 0.11 U/mL for AChE and 0.093 U/mL for BChE, physiologically relevant dynamic ranges of 2.0-18.0 U/mL for AChE and 0.5-5.0 U/mL for BChE in whole blood, and high reproducibility with the relative standard variation of <4%. The nanosensor was further validated with widely used radiometric and Ellman's methods, utilizing both <i>in vitro</i> pesticide-spiked blood samples and blood samples from 22 farmworkers. The results between this nanosensor and those two methods demonstrated a strong agreement. This platform provides a new avenue for the simple, rapid, and sensitive biomonitoring of OP pesticide exposure.
Authors
- Gregory D. Kearney (ORCID: https://orcid.org/0000-0001-9684-9516)
- Aleksandr Smirnov (ORCID: https://orcid.org/0000-0002-4886-6853)
- Carey Pope (ORCID: https://orcid.org/0000-0001-9936-3589)
- Xiuxia Du (ORCID: https://orcid.org/0000-0002-3468-9585)
- Landon Butler (ORCID: https://orcid.org/0000-0003-3299-0320)
- Phillip Summers (ORCID: https://orcid.org/0000-0001-6887-9486)
- Joshua T. Butcher (ORCID: https://orcid.org/0000-0002-7341-1949)
- Thomas A. Arcury (ORCID: https://orcid.org/0000-0001-9523-9492)
- Hussian Maanaki (ORCID: https://orcid.org/0009-0005-2166-7837)
- Yu Sun (ORCID: https://orcid.org/0000-0002-7699-0042)
- Anna Jensen
- Jun Wang (ORCID: https://orcid.org/0000-0002-5089-7309)
- Letice Bussiere (ORCID: https://orcid.org/0000-0003-2864-1814)
Institutions
- University of North Carolina at Charlotte (US)
- East Carolina University (US)
- Cytodiagnostics (Canada) (CA)
- Department of Physiological Sciences (RU)
- Oklahoma State University Oklahoma City (US)
- Wake Forest University (US)
Publication Details
- Journal
- Analytical Chemistry
- Published
- 2025-04-25
- DOI
- https://doi.org/10.1021/acs.analchem.4c06421
- Citations
- 11
- Primary Topic
- Biosensors and Analytical Detection
- Type
- article
- Field-Weighted Citation Impact
- 7.42
Funders
- National Institute of Environmental Health Sciences
- National Institute of Biomedical Imaging and Bioengineering