An Integrated Nanosensor/Smartphone Platform for Point-of-Care Biomonitoring of Human Exposure to Pesticides

Organophosphorus (OP) compounds are neurotoxins that are among the most widely used pesticides in agriculture in the United States. In this application, a new integrated point-of-care smartphone/resistive nanosensor device is developed for onsite rapid and sensitive detection of exposure to OP pesticides from a drop of finger-stick blood among a sample of farmworkers. The nanosensor leverages the transport properties of a multiwalled carbon nanotube/polyaniline nanofiber (MWCNT/PAnNF) nanocomposite film on a gold interdigitated electrode and acetylcholinesterase/butyrylcholinesterase (AChE/BChE) hydrolysis of their respective substrates generating protons doping PAnNFs, thereby increasing the conductance of the film. As such, a conductance change can be used to quantify cholinesterase activity, enabling assessment of acute/chronic OP poisoning. Additionally, a mobile app was developed for the nanosensor to process, display, track, and share results. Under optimal conditions, the nanosensor demonstrated exceptional sensitivity with the detection limits of 0.11 U/mL for AChE and 0.093 U/mL for BChE, physiologically relevant dynamic ranges of 2.0-18.0 U/mL for AChE and 0.5-5.0 U/mL for BChE in whole blood, and high reproducibility with the relative standard variation of <4%. The nanosensor was further validated with widely used radiometric and Ellman's methods, utilizing both <i>in vitro</i> pesticide-spiked blood samples and blood samples from 22 farmworkers. The results between this nanosensor and those two methods demonstrated a strong agreement. This platform provides a new avenue for the simple, rapid, and sensitive biomonitoring of OP pesticide exposure.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-25
DOI
https://doi.org/10.1021/acs.analchem.4c06421
Citations
11
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
7.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Integrated Nanosensor/Smartphone Platform for Point-of-Care Biomonitoring of Human Exposure to Pesticides

Gregory D. Kearney, Aleksandr Smirnov, Carey Pope, Xiuxia Du et al.
11 citations
Analytical Chemistry
Biosensors and Analytical Detection
7.42
article

An Integrated Nanosensor/Smartphone Platform for Point-of-Care Biomonitoring of Human Exposure to Pesticides

Gregory D. Kearney, Aleksandr Smirnov, Carey Pope, Xiuxia Du, Landon Butler, Phillip Summers, Joshua T. Butcher, Thomas A. Arcury, Hussian Maanaki, Yu Sun, Anna Jensen, Jun Wang, Letice Bussiere
article en
11 citations

Abstract

Organophosphorus (OP) compounds are neurotoxins that are among the most widely used pesticides in agriculture in the United States. In this application, a new integrated point-of-care smartphone/resistive nanosensor device is developed for onsite rapid and sensitive detection of exposure to OP pesticides from a drop of finger-stick blood among a sample of farmworkers. The nanosensor leverages the transport properties of a multiwalled carbon nanotube/polyaniline nanofiber (MWCNT/PAnNF) nanocomposite film on a gold interdigitated electrode and acetylcholinesterase/butyrylcholinesterase (AChE/BChE) hydrolysis of their respective substrates generating protons doping PAnNFs, thereby increasing the conductance of the film. As such, a conductance change can be used to quantify cholinesterase activity, enabling assessment of acute/chronic OP poisoning. Additionally, a mobile app was developed for the nanosensor to process, display, track, and share results. Under optimal conditions, the nanosensor demonstrated exceptional sensitivity with the detection limits of 0.11 U/mL for AChE and 0.093 U/mL for BChE, physiologically relevant dynamic ranges of 2.0-18.0 U/mL for AChE and 0.5-5.0 U/mL for BChE in whole blood, and high reproducibility with the relative standard variation of <4%. The nanosensor was further validated with widely used radiometric and Ellman's methods, utilizing both <i>in vitro</i> pesticide-spiked blood samples and blood samples from 22 farmworkers. The results between this nanosensor and those two methods demonstrated a strong agreement. This platform provides a new avenue for the simple, rapid, and sensitive biomonitoring of OP pesticide exposure.

Analytical ChemistryVol. 97(18)
University of North Carolina at Charlotte (US), East Carolina University (US), Cytodiagnostics (Canada) (CA), Department of Physiological Sciences (RU), Oklahoma State University Oklahoma City (US), Wake Forest University (US)
National Institute of Environmental Health Sciences, National Institute of Biomedical Imaging and Bioengineering
Zero hunger
Openalex Percentile: Top 3%
Biosensors and Analytical Detection
7.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.