IFN-γ/IL-2 Double-Color FluoroSpot Assay for Monitoring Human Primary T Cell Activation: Validation, Inter-Laboratory Comparison, and Recommendations for Clinical Studies

The enzyme-linked immunosorbent spot (EliSpot) assay and its fluorescence-based version, FluoroSpot, are sensitive immunoassays commonly used to quantify antigen-specific T and B lymphocytes and other immune cells in peripheral blood or homogenized tissues. Due to their high sensitivity, these assays are popular in clinical trials to evaluate the efficacy of immunotherapy and vaccines, which involve a high level of scrutiny to ensure valid study results. Besides industry consensus white papers and other research publications, there is no formal guidance for the industry on how to validate EliSpot and FluoroSpot assays to ensure their accurate performance for immune monitoring in clinical trials. Herein, we describe a comprehensive in vitro study using healthy human donor peripheral blood mononuclear cells (PBMCs) and model antigens to validate a double-color FluoroSpot assay for monitoring antigen-specific lymphocytes by detecting and quantifying IFN-γ and IL-2-producing lymphocytes. Validation parameters, acceptance criteria set-up, and assay limits-limit of detection (LOD), minimum positive control response, lower and upper limits of quantification (LLOQ and ULOQ)-were determined, and assay performance was demonstrated by assessing precision, specificity, linearity, and robustness. In addition, an inter-laboratory comparison demonstrated concordance between assay results from two laboratories. In summary, this study outlines a robust approach to EliSpot and FluoroSpot validation and demonstrates that the IFN-γ/IL-2 FluoroSpot assay is suitable for the reliable detection of antigen-specific immune responses from PBMC samples across laboratories and meets the current regulatory requirements for bioanalytical method validation.

Authors

Institutions

Publication Details

Journal
The AAPS Journal
Published
2025-04-25
DOI
https://doi.org/10.1208/s12248-025-01072-3
Citations
5
Primary Topic
Immune Cell Function and Interaction
Type
article
Field-Weighted Citation Impact
3.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IFN-γ/IL-2 Double-Color FluoroSpot Assay for Monitoring Human Primary T Cell Activation: Validation, Inter-Laboratory Comparison, and Recommendations for Clinical Studies

Raquel Villar-Hernández, Martín Schuster, Elisa Rusch, Marco Springer et al.
5 citations
The AAPS Journal
Immune Cell Function and Interaction
3.99
article

IFN-γ/IL-2 Double-Color FluoroSpot Assay for Monitoring Human Primary T Cell Activation: Validation, Inter-Laboratory Comparison, and Recommendations for Clinical Studies

Raquel Villar-Hernández, Martín Schuster, Elisa Rusch, Marco Springer, Rosemarie Preyer, Marina A. Dobrovolskaia, Alexandra Mauthe, Edward Cedrone, Matthias Gutekunst
article en
5 citations

Abstract

The enzyme-linked immunosorbent spot (EliSpot) assay and its fluorescence-based version, FluoroSpot, are sensitive immunoassays commonly used to quantify antigen-specific T and B lymphocytes and other immune cells in peripheral blood or homogenized tissues. Due to their high sensitivity, these assays are popular in clinical trials to evaluate the efficacy of immunotherapy and vaccines, which involve a high level of scrutiny to ensure valid study results. Besides industry consensus white papers and other research publications, there is no formal guidance for the industry on how to validate EliSpot and FluoroSpot assays to ensure their accurate performance for immune monitoring in clinical trials. Herein, we describe a comprehensive in vitro study using healthy human donor peripheral blood mononuclear cells (PBMCs) and model antigens to validate a double-color FluoroSpot assay for monitoring antigen-specific lymphocytes by detecting and quantifying IFN-γ and IL-2-producing lymphocytes. Validation parameters, acceptance criteria set-up, and assay limits-limit of detection (LOD), minimum positive control response, lower and upper limits of quantification (LLOQ and ULOQ)-were determined, and assay performance was demonstrated by assessing precision, specificity, linearity, and robustness. In addition, an inter-laboratory comparison demonstrated concordance between assay results from two laboratories. In summary, this study outlines a robust approach to EliSpot and FluoroSpot validation and demonstrates that the IFN-γ/IL-2 FluoroSpot assay is suitable for the reliable detection of antigen-specific immune responses from PBMC samples across laboratories and meets the current regulatory requirements for bioanalytical method validation.

The AAPS JournalVol. 27(4)
University of America (US), Frederick National Laboratory for Cancer Research (US), CS Diagnostics (DE)
U.S. Department of Health and Human Services, National Institutes of Health, National Cancer Institute
Industry, innovation and infrastructure
Openalex Percentile: Top 6%
Immune Cell Function and Interaction
3.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.