Multiple bias calibration for valid statistical inference under nonignorable nonresponse

Valid statistical inference is notoriously challenging when the sample is subject to nonresponse bias. We approach this difficult problem by employing multiple candidate models for the propensity score (PS) function combined with empirical likelihood. By incorporating multiple working PS models into the internal bias calibration constraint in the empirical likelihood, the selection bias can be safely eliminated as long as the working PS models contain the true model and their expectations are equal to the true missing rate. The bias calibration constraint for the multiple PS models is called the multiple bias calibration. The study delves into the asymptotic properties of the proposed method and provides a comparative analysis through limited simulation studies against existing methods. To illustrate practical implementation, we present a real data analysis on body fat percentage using the National Health and Nutrition Examination Survey dataset.

Authors

Institutions

Publication Details

Journal
Biometrics
Published
2025-04-02
DOI
https://doi.org/10.1093/biomtc/ujaf044
Citations
1
Primary Topic
Advanced Causal Inference Techniques
Type
article
Field-Weighted Citation Impact
2.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple bias calibration for valid statistical inference under nonignorable nonresponse

Seonghun Cho, Yumou Qiu, Jae Kwang Kim
1 citations
Biometrics
Advanced Causal Inference Techniques
2.63
article

Multiple bias calibration for valid statistical inference under nonignorable nonresponse

Seonghun Cho, Yumou Qiu, Jae Kwang Kim
article en
1 citations

Abstract

Valid statistical inference is notoriously challenging when the sample is subject to nonresponse bias. We approach this difficult problem by employing multiple candidate models for the propensity score (PS) function combined with empirical likelihood. By incorporating multiple working PS models into the internal bias calibration constraint in the empirical likelihood, the selection bias can be safely eliminated as long as the working PS models contain the true model and their expectations are equal to the true missing rate. The bias calibration constraint for the multiple PS models is called the multiple bias calibration. The study delves into the asymptotic properties of the proposed method and provides a comparative analysis through limited simulation studies against existing methods. To illustrate practical implementation, we present a real data analysis on body fat percentage using the National Health and Nutrition Examination Survey dataset.

BiometricsVol. 81(2)
Iowa State University (US), Inha University (KR), Peking University (CN)
National Science Foundation, U.S. Department of Agriculture, National Research Foundation, National Natural Science Foundation of China, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Zero hunger
Openalex Percentile: Top 12%
Advanced Causal Inference Techniques
2.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multiple bias calibration for valid statistical inference under nonignorable nonresponse — Seonghun Cho, Yumou Qiu, et al. · Biometrics (2025) | TGRS Research Map | TGRS