Fixed distance based determination of normative range of median nerve electro-diagnostic parameters

Objectives Nerve conduction study is important diagnostic tool for exploring the median nerve neuropathy. This study aims to explore reference electrophysiological values for the median nerve in a sample of the East Indian population for normative data based on various anthropometric parameters and fixed distance recording among healthy adult subjects. Materials and Methods The study was cross-sectional at the All India Institute of Medical Sciences, Kalyani, West Bengal. After a thorough clinical evaluation, 128 hands of 64 healthy volunteers, aged between 18 and 60 years, were chosen for screening for systemic diseases or any major conditions affecting the nerves and muscles. The lengths of the arm, forearm, and wrist circumference were measured at specific reference distances. Nerve conduction studies (NCS) were carried out following standardized protocols. Motor nerve conduction data collection included median nerve distal latency, distal amplitude (DAmp), proximal latency, proximal amplitude, and conduction velocity (CV). Sensory nerve conduction data included onset latency, DAmp, and CV at 120 mm, 140 mm, and 160 mm distances from the site of stimulation. Data analysis was performed using the Statistical Package for the Social Sciences version 22. Results The mean and standard deviation of all parameters were calculated. NCS parameters were also determined at various percentiles. Linear regression models showed a negative link between sensory median nerve latency and increased distance from the point of stimulation. The models also provided coefficients indicating changes in NCS parameters for unit changes in body mass index (kg/m 2 ), arm length, forearm length, and wrist circumference, individually for males and females. Conclusion The study identified variations in median nerve electrophysiological values, with regression models demonstrating different associations with various parameters.

Authors

Institutions

Publication Details

Journal
Journal of Neurosciences in Rural Practice
Published
2025-04-24
DOI
https://doi.org/10.25259/jnrp_310_2024
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fixed distance based determination of normative range of median nerve electro-diagnostic parameters

Manjusha Shinde, A. Shaikh, T. K. Ghosh, Sanjay Patel
Journal of Neurosciences in Rural Practice
Neuroscience and Neural Engineering
article

Fixed distance based determination of normative range of median nerve electro-diagnostic parameters

Manjusha Shinde, A. Shaikh, T. K. Ghosh, Sanjay Patel
article en

Abstract

Objectives Nerve conduction study is important diagnostic tool for exploring the median nerve neuropathy. This study aims to explore reference electrophysiological values for the median nerve in a sample of the East Indian population for normative data based on various anthropometric parameters and fixed distance recording among healthy adult subjects. Materials and Methods The study was cross-sectional at the All India Institute of Medical Sciences, Kalyani, West Bengal. After a thorough clinical evaluation, 128 hands of 64 healthy volunteers, aged between 18 and 60 years, were chosen for screening for systemic diseases or any major conditions affecting the nerves and muscles. The lengths of the arm, forearm, and wrist circumference were measured at specific reference distances. Nerve conduction studies (NCS) were carried out following standardized protocols. Motor nerve conduction data collection included median nerve distal latency, distal amplitude (DAmp), proximal latency, proximal amplitude, and conduction velocity (CV). Sensory nerve conduction data included onset latency, DAmp, and CV at 120 mm, 140 mm, and 160 mm distances from the site of stimulation. Data analysis was performed using the Statistical Package for the Social Sciences version 22. Results The mean and standard deviation of all parameters were calculated. NCS parameters were also determined at various percentiles. Linear regression models showed a negative link between sensory median nerve latency and increased distance from the point of stimulation. The models also provided coefficients indicating changes in NCS parameters for unit changes in body mass index (kg/m 2 ), arm length, forearm length, and wrist circumference, individually for males and females. Conclusion The study identified variations in median nerve electrophysiological values, with regression models demonstrating different associations with various parameters.

Journal of Neurosciences in Rural PracticeVol. 16
All India Institute of Medical Sciences (IN)
Openalex Percentile: Top 90%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.