Evaluating Rebound Hypotension Following Vasopressor Discontinuation Strategies in Patients With Septic Shock
During the study period, 580 patients were evaluated for inclusion, of which 209 were included: 150 in the NE1 group and 59 in the AVP1 group. There was no difference in incidence of hypotension within 6 (54% vs 61%), 6-12 (14.7% vs 10.2%), or 12-24 (6.7% vs 10.2%) hours, ICU LOS, ICU mortality, and shock resolution between groups. The Kaplan-Meier curve showed no differences between groups in time to hypotension within 6 hours of vasopressor discontinuation (<i>p</i> = 0.1)Conclusion and Relevance:This is the first study to evaluate the impact of vasopressor discontinuation order in septic shock within 6 hours, finding no differences in hypotension regardless of discontinuation order. Application of this data gives reassurance the order of vasopressor discontinuation may not impact clinical outcomes.
Authors
- Jeremy R. DeGrado (ORCID: https://orcid.org/0000-0002-0141-7137)
- Brian R. Schuler (ORCID: https://orcid.org/0000-0002-7997-649X)
- Kevin M. Dube (ORCID: https://orcid.org/0000-0002-3723-4586)
- Paul M. Szumita (ORCID: https://orcid.org/0000-0002-3679-7037)
- Skyler Starkel (ORCID: https://orcid.org/0009-0005-2346-657X)
Institutions
- Brigham and Women's Hospital (US)
Publication Details
- Journal
- Annals of Pharmacotherapy
- Published
- 2025-04-24
- DOI
- https://doi.org/10.1177/10600280251335344
- Citations
- 2
- Primary Topic
- Sepsis Diagnosis and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 2.71