Quantifying Gas Leak Rates through Regolith Feed Columns in Vacuum

All in situ resource utilization regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems that use a series of mechanical valves to reduce mass and complexity. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady-state pressure gradient equilibria, demonstrating a linear relationship between column height and resulting leak rate. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10−5 up to 760 Torr to corroborate ambient tests from previous work. Pressure decay rates decreased up to 27-fold under vacuum when compared to equal differentials relative to ambient pressure, demonstrating the importance of vacuum testing for regolith seal systems. Disrupted regolith simulant was found to exhibit higher leak rates than pristine, as-poured simulant, indicating the need to consider the impact of recovery from depressurization events. Both GRC-1 and OB-1 lunar regolith simulants were used to demonstrate seal sensitivity to regolith mechanical properties.

Authors

Institutions

Publication Details

Journal
Journal of Aerospace Engineering
Published
2025-04-24
DOI
https://doi.org/10.1061/jaeeez.aseng-5664
Primary Topic
Gas Dynamics and Kinetic Theory
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying Gas Leak Rates through Regolith Feed Columns in Vacuum

J.W. Stewart
Journal of Aerospace Engineering
Gas Dynamics and Kinetic Theory
article

Quantifying Gas Leak Rates through Regolith Feed Columns in Vacuum

J.W. Stewart
article en

Abstract

All in situ resource utilization regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems that use a series of mechanical valves to reduce mass and complexity. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady-state pressure gradient equilibria, demonstrating a linear relationship between column height and resulting leak rate. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10−5 up to 760 Torr to corroborate ambient tests from previous work. Pressure decay rates decreased up to 27-fold under vacuum when compared to equal differentials relative to ambient pressure, demonstrating the importance of vacuum testing for regolith seal systems. Disrupted regolith simulant was found to exhibit higher leak rates than pristine, as-poured simulant, indicating the need to consider the impact of recovery from depressurization events. Both GRC-1 and OB-1 lunar regolith simulants were used to demonstrate seal sensitivity to regolith mechanical properties.

Journal of Aerospace EngineeringVol. 38(4)
Glenn Research Center (US)
Affordable and clean energy
Openalex Percentile: Top 88%
Gas Dynamics and Kinetic Theory
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.