Topologically Optimized Anthropomorphic Prosthetic Limb: Finite Element Analysis and Mechanical Evaluation Using Plantogram-Derived Foot Pressure Data

The development of prosthetic limbs has benefited individuals who suffered amputations due to accidents or medical conditions. During the development of conventional prosthetics, several challenges have been observed regarding the functional limitations, the restricted degrees of freedom compared to an actual human limb, and the biocompatibility issues between the surface of the prosthetic limb and the human tissue or skin. These issues could result in mobility impairments due to failed mimicry of the actual stress distribution, causing discomfort, chronic pain, and tissue damage or possible infections. Especially in cases where underlying conditions exist, such as diabetes, possible trauma, or vascular disease, a failed adaptation of the prosthetic limb could lead to complete abandonment of the prosthetic part. To address these challenges, the insertion of topologically optimized parts with a biomimetic approach has allowed the optimization of the mimicry of the complex functionality behavior of the natural body parts, allowing the development of lightweight efficient anthropomorphic structures. This approach results in unified stress distribution, minimizing the practical limitations while also adding an aesthetic that aids in reducing any possible symptoms related to social anxiety and impaired social functioning. In this paper, the development of a novel anthropomorphic designed prosthetic foot with a novel Thermoplastic Polyurethane-based composite (TPU-Ground Tire Rubber 10 wt.%) was studied. The final designs contain advanced sustainable polymeric materials, gyroid lattice geometries, and Finite Element Analysis (FEA) for performance optimization. Initially, a static evaluation was conducted to replicate the phenomena at the standing process of a conventional replicated above-knee prosthetic. Furthermore, dynamic testing was conducted to assess the mechanical responses to high-intensity exercises (e.g., sprinting, jumping). The evaluation of the dynamic mechanical response of the prosthetic limb was compared to actual plantogram-derived foot pressure data during static phases (standing, light walking) and dynamic phenomena (sprinting, jumping) to address the optimal geometry and density, ensuring maximum compatibility. This innovative approach allows the development of tailored prosthetic limbs with optimal replication of the human motion patterns, resulting in improved patient outcomes and higher success rates. The proposed design presented hysteretic damping factor and energy absorption efficiency adequate for load handling of intense exercises (0.18 loss factor, 57% energy absorption efficiency) meaning that it is suitable for further research and possible upcycling.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2025-04-24
DOI
https://doi.org/10.3390/biomimetics10050261
Citations
2
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Topologically Optimized Anthropomorphic Prosthetic Limb: Finite Element Analysis and Mechanical Evaluation Using Plantogram-Derived Foot Pressure Data

Dimitrios Tzetzis, Konstantinos Tsongas, Eleftheria Maria Pechlivani, Nikolaos Kladovasilakis et al.
2 citations
Biomimetics
Prosthetics and Rehabilitation Robotics
1.35
article

Topologically Optimized Anthropomorphic Prosthetic Limb: Finite Element Analysis and Mechanical Evaluation Using Plantogram-Derived Foot Pressure Data

Dimitrios Tzetzis, Konstantinos Tsongas, Eleftheria Maria Pechlivani, Nikolaos Kladovasilakis, Ioannis Filippos Kyriakidis, Marios Gavriilopoulos
article en
2 citations

Abstract

The development of prosthetic limbs has benefited individuals who suffered amputations due to accidents or medical conditions. During the development of conventional prosthetics, several challenges have been observed regarding the functional limitations, the restricted degrees of freedom compared to an actual human limb, and the biocompatibility issues between the surface of the prosthetic limb and the human tissue or skin. These issues could result in mobility impairments due to failed mimicry of the actual stress distribution, causing discomfort, chronic pain, and tissue damage or possible infections. Especially in cases where underlying conditions exist, such as diabetes, possible trauma, or vascular disease, a failed adaptation of the prosthetic limb could lead to complete abandonment of the prosthetic part. To address these challenges, the insertion of topologically optimized parts with a biomimetic approach has allowed the optimization of the mimicry of the complex functionality behavior of the natural body parts, allowing the development of lightweight efficient anthropomorphic structures. This approach results in unified stress distribution, minimizing the practical limitations while also adding an aesthetic that aids in reducing any possible symptoms related to social anxiety and impaired social functioning. In this paper, the development of a novel anthropomorphic designed prosthetic foot with a novel Thermoplastic Polyurethane-based composite (TPU-Ground Tire Rubber 10 wt.%) was studied. The final designs contain advanced sustainable polymeric materials, gyroid lattice geometries, and Finite Element Analysis (FEA) for performance optimization. Initially, a static evaluation was conducted to replicate the phenomena at the standing process of a conventional replicated above-knee prosthetic. Furthermore, dynamic testing was conducted to assess the mechanical responses to high-intensity exercises (e.g., sprinting, jumping). The evaluation of the dynamic mechanical response of the prosthetic limb was compared to actual plantogram-derived foot pressure data during static phases (standing, light walking) and dynamic phenomena (sprinting, jumping) to address the optimal geometry and density, ensuring maximum compatibility. This innovative approach allows the development of tailored prosthetic limbs with optimal replication of the human motion patterns, resulting in improved patient outcomes and higher success rates. The proposed design presented hysteretic damping factor and energy absorption efficiency adequate for load handling of intense exercises (0.18 loss factor, 57% energy absorption efficiency) meaning that it is suitable for further research and possible upcycling.

BiomimeticsVol. 10(5)
International Hellenic University (GR), Information Technologies Institute (GR), Centre for Research and Technology Hellas (GR)
Openalex Percentile: Top 21%
Prosthetics and Rehabilitation Robotics
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.