COMPARISON OF HOT WATER HEATER CONNECTION SCHEMES FOR DISTRICT HEATING STATIONS IN INSULATED BUILDINGS

One way to improve efficiency micro-district centralized heat supply systems - transition from group thermal substations, where water is prepared for consumption of hot water supply, distribution of heat transfer by types of water supply, regulation of hydraulic and thermal regimes in microdistrict thermal limits, the volume of accumulated heat, up to individual district heating stations. The technological scheme of the individual district heating stations transfers all the necessary functions for the heat supply of the surrounding area construction. One of the advantages of such an approach is the possibility of transition to a two-pipe split thermal boundaries and changes in heat consumption by pipelines microdistrict boundaries A comparison was performed of the network water flow rates through individual district heating stations and the heat transfer surface area of domestic hot water heating installations in insulated buildings. The study analyzed two-stage mixed and two-stage sequential connection schemes of hot water heaters to district heating networks. It was shown that the use of two-stage schemes, as opposed to single-stage schemes, significantly reduces the network water flow through individual district heating stations. This effect is achieved by increasing the heat transfer surface area of heat exchangers in domestic hot water heating systems installed in individual district heating stations compared to single-stage schemes. For heating installations using the two-stage mixed connection scheme, larger heat transfer surface areas are expected compared to the two-stage sequential connection scheme. The excess surface area ranges from 10% to 70%, depending on the building's insulation efficiency and the design temperature for water heating at the first stage of the domestic hot water heating system. A formula was proposed to determine the water heating temperature at the first stage of the heating installation, at which the network water flow rate through the individual district heating station in the two-stage mixed scheme is lower than that in the two-stage sequential scheme. At a significant temperature rise, water heating at the first stage of the heating installation for individual district heating stations with insulation increased to more than 25℃, as a result of the increase in the total heat transfer area of the heat exchangers. installation equipment.

Authors

Institutions

Publication Details

Journal
Municipal economy of cities
Published
2025-04-02
DOI
https://doi.org/10.33042/2522-1809-2025-1-189-233-237
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARISON OF HOT WATER HEATER CONNECTION SCHEMES FOR DISTRICT HEATING STATIONS IN INSULATED BUILDINGS

A. Boblovskii, O. Kruhliakova, O.A. leksakhin, M. Rudneva
Municipal economy of cities
Building Energy and Comfort Optimization
article

COMPARISON OF HOT WATER HEATER CONNECTION SCHEMES FOR DISTRICT HEATING STATIONS IN INSULATED BUILDINGS

A. Boblovskii, O. Kruhliakova, O.A. leksakhin, M. Rudneva
article en

Abstract

One way to improve efficiency micro-district centralized heat supply systems - transition from group thermal substations, where water is prepared for consumption of hot water supply, distribution of heat transfer by types of water supply, regulation of hydraulic and thermal regimes in microdistrict thermal limits, the volume of accumulated heat, up to individual district heating stations. The technological scheme of the individual district heating stations transfers all the necessary functions for the heat supply of the surrounding area construction. One of the advantages of such an approach is the possibility of transition to a two-pipe split thermal boundaries and changes in heat consumption by pipelines microdistrict boundaries A comparison was performed of the network water flow rates through individual district heating stations and the heat transfer surface area of domestic hot water heating installations in insulated buildings. The study analyzed two-stage mixed and two-stage sequential connection schemes of hot water heaters to district heating networks. It was shown that the use of two-stage schemes, as opposed to single-stage schemes, significantly reduces the network water flow through individual district heating stations. This effect is achieved by increasing the heat transfer surface area of heat exchangers in domestic hot water heating systems installed in individual district heating stations compared to single-stage schemes. For heating installations using the two-stage mixed connection scheme, larger heat transfer surface areas are expected compared to the two-stage sequential connection scheme. The excess surface area ranges from 10% to 70%, depending on the building's insulation efficiency and the design temperature for water heating at the first stage of the domestic hot water heating system. A formula was proposed to determine the water heating temperature at the first stage of the heating installation, at which the network water flow rate through the individual district heating station in the two-stage mixed scheme is lower than that in the two-stage sequential scheme. At a significant temperature rise, water heating at the first stage of the heating installation for individual district heating stations with insulation increased to more than 25℃, as a result of the increase in the total heat transfer area of the heat exchangers. installation equipment.

Municipal economy of citiesVol. 1(189)
O.M. Beketov National University of Urban Economy in Kharkiv (UA), Physicotechnical Institute (UZ), National Technical University "Kharkiv Polytechnic Institute" (UA), V. N. Karazin Kharkiv National University (UA)
Openalex Percentile: Top 92%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.