Feasibility and Safety Properties of Metabolic-Flow Anesthesia Driven by Automated Gas Control® in Pediatric Patients: A Prospective Observational Study

<i>Background and Objectives</i>: Metabolic-flow (<0.35 L/min) anesthesia is practiced more often as manufacturers provide newer technologies, yet the benefits of metabolic-flow anesthesia have not been fully investigated. This study aimed to investigate the feasibility and safety of automated gas control (AGC<sup>®</sup>) mode, which provides metabolic-flow anesthesia, in a pediatric population. <i>Materials and Methods</i>: Pediatric surgery patients between 1 and 10 years of age were included in this prospective observational trial. After intravenous induction and safe orotracheal intubation, AGC<sup>®</sup> was initiated, and total sevoflurane consumption (mL) and wash-in speed-based sevoflurane consumption data were collected to measure feasibility. For safety, inspired (F<sub>i</sub>O<sub>2</sub>), alveolar (F<sub>A</sub>O<sub>2</sub>), and expired (F<sub>E</sub>O<sub>2</sub>) oxygen concentration data, and inspired and alveolar sevoflurane (F<sub>i</sub>Sevo and F<sub>A</sub>Sevo, respectively) concentration data, were recorded. Changes in fresh gas flow (FGF) throughout the procedure and postoperative recovery data were also compared. <i>Results</i>: A total of 130 patients were eligible for this study, and 121 patients were included in the analyses; 30 patients had a wash-in speed of 4 (WI4) and 91 patients had a wash-in speed of 8 (WI8) at follow-up. The total mean sevoflurane consumption was 9.35 ± 4.93 mL for a median surgery duration of 100 min. WI8 patients consumed more sevoflurane (9.92 ± 5.08 mL vs. 7.79 ± 4.19 mL, <i>p</i> = 0.04). At the 15th and 30th minutes, the FGF dropped under minimal flow and metabolic flow limits, respectively (<i>p</i> < 0.001). The times to extubation and obeying commands were shorter in WI8 patients (8 (5-10) vs. 11 (5-15) <i>p</i> = 0.03, and 9.5 (5-10.5) vs. 13 (9-17) <i>p</i> < 0.01). <i>Conclusions</i>: Maintenance with AGC<sup>®</sup> may offer up to 40 h of anesthesia, considering that the volume of a sevoflurane bottle is 250 mL, reflecting exceptional savings compared to conventional anesthesia management. Metabolic flow anesthesia driven by AGC<sup>®</sup> is feasible and safe in pediatric anesthesia practice.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-04-24
DOI
https://doi.org/10.3390/medicina61050786
Citations
2
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
4.38
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and Safety Properties of Metabolic-Flow Anesthesia Driven by Automated Gas Control® in Pediatric Patients: A Prospective Observational Study

Ayşe Gülşah Atasever, Emre Sertaç Bingül, Meltem Savran Karadeniz, Emre Şentürk et al.
2 citations
Medicina
Anesthesia and Sedative Agents
4.38
article

Feasibility and Safety Properties of Metabolic-Flow Anesthesia Driven by Automated Gas Control® in Pediatric Patients: A Prospective Observational Study

Ayşe Gülşah Atasever, Emre Sertaç Bingül, Meltem Savran Karadeniz, Emre Şentürk, Mukadder Orhan Sungur, İrem Vuran Yaz
article en
2 citations

Abstract

<i>Background and Objectives</i>: Metabolic-flow (<0.35 L/min) anesthesia is practiced more often as manufacturers provide newer technologies, yet the benefits of metabolic-flow anesthesia have not been fully investigated. This study aimed to investigate the feasibility and safety of automated gas control (AGC<sup>®</sup>) mode, which provides metabolic-flow anesthesia, in a pediatric population. <i>Materials and Methods</i>: Pediatric surgery patients between 1 and 10 years of age were included in this prospective observational trial. After intravenous induction and safe orotracheal intubation, AGC<sup>®</sup> was initiated, and total sevoflurane consumption (mL) and wash-in speed-based sevoflurane consumption data were collected to measure feasibility. For safety, inspired (F<sub>i</sub>O<sub>2</sub>), alveolar (F<sub>A</sub>O<sub>2</sub>), and expired (F<sub>E</sub>O<sub>2</sub>) oxygen concentration data, and inspired and alveolar sevoflurane (F<sub>i</sub>Sevo and F<sub>A</sub>Sevo, respectively) concentration data, were recorded. Changes in fresh gas flow (FGF) throughout the procedure and postoperative recovery data were also compared. <i>Results</i>: A total of 130 patients were eligible for this study, and 121 patients were included in the analyses; 30 patients had a wash-in speed of 4 (WI4) and 91 patients had a wash-in speed of 8 (WI8) at follow-up. The total mean sevoflurane consumption was 9.35 ± 4.93 mL for a median surgery duration of 100 min. WI8 patients consumed more sevoflurane (9.92 ± 5.08 mL vs. 7.79 ± 4.19 mL, <i>p</i> = 0.04). At the 15th and 30th minutes, the FGF dropped under minimal flow and metabolic flow limits, respectively (<i>p</i> < 0.001). The times to extubation and obeying commands were shorter in WI8 patients (8 (5-10) vs. 11 (5-15) <i>p</i> = 0.03, and 9.5 (5-10.5) vs. 13 (9-17) <i>p</i> < 0.01). <i>Conclusions</i>: Maintenance with AGC<sup>®</sup> may offer up to 40 h of anesthesia, considering that the volume of a sevoflurane bottle is 250 mL, reflecting exceptional savings compared to conventional anesthesia management. Metabolic flow anesthesia driven by AGC<sup>®</sup> is feasible and safe in pediatric anesthesia practice.

MedicinaVol. 61(5)
Istanbul University (TR), KU Leuven (BE)
Openalex Percentile: Top 7%
Anesthesia and Sedative Agents
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.