REVIEW OF 3-STORY PLATE STRUCTURAL DESIGN OF SOLOK POLRES FLAT BUILDING, WEST SUMATRA

The 3-storey building of the Solok District Police Flat located in Koto Gaek Guguak, Gunung Talang District, Solok Regency is a state building that functions as a means of carrying out state duties by the Police at the Solok District Police to maximize performance. Therefore, a building that suits the needs and has a stable and strong structure that can withstand static loads and potential disasters such as earthquakes is needed, because the Solok Regency area is a fault area prone to earthquakes. The initial design of the building's upper structure seemed uneconomical, especially in the floor plate section. The author reviewed the planning of the upper structure of the floor plate section by referring to building construction regulations and earthquake resistance. This research uses a descriptive qualitative method. Data were collected through literature review and field observation. The data was analyzed using the Microfoft Excell application. Analysis of the comparison of the initial design with the construction design plan shows that the results of the calculations carried out have a reinforcement shrinkage on the S1 type floor plate of 37.50% and a reinforcement shrinkage on the S2 type floor plate of 25.00%.

Authors

Publication Details

Journal
Journal of Scientech Research and Development
Published
2024-12-31
DOI
https://doi.org/10.56670/jsrd.v6i2.823
Primary Topic
Geotechnical and construction materials studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

REVIEW OF 3-STORY PLATE STRUCTURAL DESIGN OF SOLOK POLRES FLAT BUILDING, WEST SUMATRA

Al Azhar, Adrian Fadhli, Hardi Wijaya
Journal of Scientech Research and Development
Geotechnical and construction materials studies
article

REVIEW OF 3-STORY PLATE STRUCTURAL DESIGN OF SOLOK POLRES FLAT BUILDING, WEST SUMATRA

Al Azhar, Adrian Fadhli, Hardi Wijaya
article en

Abstract

The 3-storey building of the Solok District Police Flat located in Koto Gaek Guguak, Gunung Talang District, Solok Regency is a state building that functions as a means of carrying out state duties by the Police at the Solok District Police to maximize performance. Therefore, a building that suits the needs and has a stable and strong structure that can withstand static loads and potential disasters such as earthquakes is needed, because the Solok Regency area is a fault area prone to earthquakes. The initial design of the building's upper structure seemed uneconomical, especially in the floor plate section. The author reviewed the planning of the upper structure of the floor plate section by referring to building construction regulations and earthquake resistance. This research uses a descriptive qualitative method. Data were collected through literature review and field observation. The data was analyzed using the Microfoft Excell application. Analysis of the comparison of the initial design with the construction design plan shows that the results of the calculations carried out have a reinforcement shrinkage on the S1 type floor plate of 37.50% and a reinforcement shrinkage on the S2 type floor plate of 25.00%.

Journal of Scientech Research and DevelopmentVol. 6(2)
Openalex Percentile: Top 68%
Geotechnical and construction materials studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

REVIEW OF 3-STORY PLATE STRUCTURAL DESIGN OF SOLOK POLRES FLAT BUILDING, WEST SUMATRA — Al Azhar, Adrian Fadhli, et al. · Journal of Scientech Research and Development (2024) | TGRS Research Map | TGRS