Waveform calibration of the SND electromagnetic calorimeter

The Spherical Neutral Detector (SND) is intended for the study electron-positron annihilation processes operating at VEPP-2000 e+e- collider, which is located at Novosibirsk, Russia. The main part of the SND detector is a three-layer electromagnetic calorimeter (EMC). The EMC is equipped with spectrometric channel, which provides measurement of the calorimeter signal arrival time and amplitude with 1 ns and 250 keV resolutions, respectively. It's necessary for providing reliable detection of low-speed anti-neutrons, which are produced in $\text{e}^+\text{e}^-\rightarrow \text{n} \bar{\text{n}}$ reaction near threshold. The algorithm of determination of signal parameters (time, amplitude) is based on invariability of the signal waveform. The waveform calibration procedure using generator signals and Bhabha scattering events is presented here.

Authors

Publication Details

Published
2025-04-24
DOI
https://doi.org/10.22323/1.468.0068
Primary Topic
Advanced NMR Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Waveform calibration of the SND electromagnetic calorimeter

A. A. Korol, A.I. Tekut’ev, V. Zhulanov, N. A. Melnikova et al.
Advanced NMR Techniques and Applications
article

Waveform calibration of the SND electromagnetic calorimeter

A. A. Korol, A.I. Tekut’ev, V. Zhulanov, N. A. Melnikova, Y. Usov, S. I. Serednyakov, М. Н. Ачасов, I. K. Surin, V. P. Druzhinin, D. P. Kovrizhin, A. G. Bogdanchikov
article en

Abstract

The Spherical Neutral Detector (SND) is intended for the study electron-positron annihilation processes operating at VEPP-2000 e+e- collider, which is located at Novosibirsk, Russia. The main part of the SND detector is a three-layer electromagnetic calorimeter (EMC). The EMC is equipped with spectrometric channel, which provides measurement of the calorimeter signal arrival time and amplitude with 1 ns and 250 keV resolutions, respectively. It's necessary for providing reliable detection of low-speed anti-neutrons, which are produced in $\text{e}^+\text{e}^-\rightarrow \text{n} \bar{\text{n}}$ reaction near threshold. The algorithm of determination of signal parameters (time, amplitude) is based on invariability of the signal waveform. The waveform calibration procedure using generator signals and Bhabha scattering events is presented here.

Russian Science Foundation
Affordable and clean energy
Openalex Percentile: Top 92%
Advanced NMR Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Waveform calibration of the SND electromagnetic calorimeter — A. A. Korol, A.I. Tekut’ev, et al. · (2025) | TGRS Research Map | TGRS