Beam tracker system for the BM@N/NICA experiment

A new beam tracker system for BM@N experiment was developed and implemented in the recent experimental run with Xe beam. The tracker consists of three double sided silicon detectors, which determine beam ion trajectory in each event. Design parameters of the system are driven by the requirements of the experiment: ability to operate in beams of light and heavy ions, to cover relatively large transverse width of the beam profile, and to measure with sufficient accuracy the beam ion position and impact angle at the target. Each detector has 61x61 mm^2 active area, 128 strips on each of the p+ and n+ sides (450 μm pitch), with orthogonal orientation of strips. The detectors are 175 μm thick, placed in vacuum, and positioned 1 m apart from each other along the beam direction. The front-end electronics of the detectors is developed based on ASIC VATA64HDR16.2 (IDEAS, Norway) with large dynamic range (-20 pC / +50 pC). The read-out electronics is placed outside of vacuum and is not subject to radiation damage. The detailed characteristics of the beam tracker detectors and front-end electronics are presented, as well as operational performance of the system in the experiment with Xe beam.

Authors

Institutions

Publication Details

Published
2025-04-24
DOI
https://doi.org/10.22323/1.468.0124
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beam tracker system for the BM@N/NICA experiment

S. M. Piyadin, S. Novozhilov, M. Kapishin, Denis Chemezov et al.
Particle Detector Development and Performance
article

Beam tracker system for the BM@N/NICA experiment

S. M. Piyadin, S. Novozhilov, M. Kapishin, Denis Chemezov, S. Sedykh, Ekaterina Streletskaya, О. В. Тарасов, Evgenii Martovitsky, Yu. L. Kopylov, S. Khabarov, Nikolay Zamyatin
article en

Abstract

A new beam tracker system for BM@N experiment was developed and implemented in the recent experimental run with Xe beam. The tracker consists of three double sided silicon detectors, which determine beam ion trajectory in each event. Design parameters of the system are driven by the requirements of the experiment: ability to operate in beams of light and heavy ions, to cover relatively large transverse width of the beam profile, and to measure with sufficient accuracy the beam ion position and impact angle at the target. Each detector has 61x61 mm^2 active area, 128 strips on each of the p+ and n+ sides (450 μm pitch), with orthogonal orientation of strips. The detectors are 175 μm thick, placed in vacuum, and positioned 1 m apart from each other along the beam direction. The front-end electronics of the detectors is developed based on ASIC VATA64HDR16.2 (IDEAS, Norway) with large dynamic range (-20 pC / +50 pC). The read-out electronics is placed outside of vacuum and is not subject to radiation damage. The detailed characteristics of the beam tracker detectors and front-end electronics are presented, as well as operational performance of the system in the experiment with Xe beam.

Joint Institute for Nuclear Research (RU)
Affordable and clean energy
Openalex Percentile: Top 96%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Beam tracker system for the BM@N/NICA experiment — S. M. Piyadin, S. Novozhilov, et al. · (2025) | TGRS Research Map | TGRS