The Effect of Cut-Off Frequency on Signal Features When Filtering Equine sEMG Signal from Selected Extensor Muscles

The use of surface electromyography (sEMG) in equine locomotion research has increased significantly due to the essential role of balanced, symmetrical, and efficient movement in riding. However, variations in sEMG signal processing for forelimb extensor muscles across studies have made cross-study comparisons challenging. This study aims to compare the sEMG signal characteristics from carpal extensor muscles under different filtering methods: raw signal, low-pass filtering (10 Hz cut-off), and bandpass filtering (40–450 Hz cut-off and 7–200 Hz cut-off). sEMG signals were collected from four muscles of three horses during walking and trotting. The raw signals were normalized and filtered separately using a 4th-order Butterworth filter: low-pass 10 Hz, bandpass 40–450 Hz, or bandpass 7–200 Hz. For each filtered signal variant, eight activity bursts were annotated, and amplitude, root mean square (RMS), median frequency (MF), and signal-to-noise ratio (SNR) were extracted. Signal loss and residual signal were calculated to assess noise reduction and data retention. For m. extensor digitorum lateralis and m. extensor carpi ulnaris, bandpass filtering at 40–450 Hz resulted in the lowest signal loss and the highest amplitude, RMS, MF, and SNR after filtering. However, variations were observed for the other two carpal extensors. These findings support the hypotheses that the characteristics of myoelectric activity in equine carpal extensors vary depending on the filtering method applied and differ among individual muscles, thereby guiding future research on sEMG signal processing and, consequently, equine biomechanics. Since both noise and its reduction alter raw sEMG signals, potentially affecting data analysis, this study provides valuable insights for improving the reliability and reproducibility of equine biomechanics research across different sEMG studies.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-04-24
DOI
https://doi.org/10.3390/app15094737
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Cut-Off Frequency on Signal Features When Filtering Equine sEMG Signal from Selected Extensor Muscles

Małgorzata Domino, Ḃ. Turek, Marta Borowska, Elżbieta Stefanik et al.
2 citations
Applied Sciences
Muscle activation and electromyography studies
1.35
article

The Effect of Cut-Off Frequency on Signal Features When Filtering Equine sEMG Signal from Selected Extensor Muscles

Małgorzata Domino, Ḃ. Turek, Marta Borowska, Elżbieta Stefanik, Natalia Domańska-Kruppa
article en
2 citations

Abstract

The use of surface electromyography (sEMG) in equine locomotion research has increased significantly due to the essential role of balanced, symmetrical, and efficient movement in riding. However, variations in sEMG signal processing for forelimb extensor muscles across studies have made cross-study comparisons challenging. This study aims to compare the sEMG signal characteristics from carpal extensor muscles under different filtering methods: raw signal, low-pass filtering (10 Hz cut-off), and bandpass filtering (40–450 Hz cut-off and 7–200 Hz cut-off). sEMG signals were collected from four muscles of three horses during walking and trotting. The raw signals were normalized and filtered separately using a 4th-order Butterworth filter: low-pass 10 Hz, bandpass 40–450 Hz, or bandpass 7–200 Hz. For each filtered signal variant, eight activity bursts were annotated, and amplitude, root mean square (RMS), median frequency (MF), and signal-to-noise ratio (SNR) were extracted. Signal loss and residual signal were calculated to assess noise reduction and data retention. For m. extensor digitorum lateralis and m. extensor carpi ulnaris, bandpass filtering at 40–450 Hz resulted in the lowest signal loss and the highest amplitude, RMS, MF, and SNR after filtering. However, variations were observed for the other two carpal extensors. These findings support the hypotheses that the characteristics of myoelectric activity in equine carpal extensors vary depending on the filtering method applied and differ among individual muscles, thereby guiding future research on sEMG signal processing and, consequently, equine biomechanics. Since both noise and its reduction alter raw sEMG signals, potentially affecting data analysis, this study provides valuable insights for improving the reliability and reproducibility of equine biomechanics research across different sEMG studies.

Applied SciencesVol. 15(9)
Bialystok University of Technology (PL), Warsaw University of Life Sciences (PL)
Openalex Percentile: Top 21%
Muscle activation and electromyography studies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.