Determination of Gaseous H2O2 Using UV-Vis Spectroscopy

The detection of gases and volatile compounds remains a significant analytical challenge, particularly in terms of sensitivity and selectivity. Many situations require rapid, sensitive, and yet easy-to-operate methods for detecting gaseous hydrogen peroxide (H2O2) under ambient conditions. In this study, we present two novel methodologies for the real-time monitoring of gaseous H2O2 based on colorimetric reactions, which are quantitatively analysed using UV-vis spectrometry. The proposed methods demonstrate high sensitivity in the low mg m−3 range, with a broad linear response within the tested concentration ranges of 0.4–17.6 mg m−3 and 10–90 mg m−3 after 20 min of accumulation under room-temperature conditions. The simplicity of the experimental setup, combined with robust analytical performance, highlights the potential applications of these methods in emerging fields such as clinical diagnostics, explosives detection, environmental monitoring, and occupational health and safety.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-04-24
DOI
https://doi.org/10.3390/chemosensors13050157
Citations
2
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Gaseous H2O2 Using UV-Vis Spectroscopy

Vasko Jovanovski, Aaron Modic, Larisa Filip
2 citations
Chemosensors
Water Quality Monitoring and Analysis
1.99
article

Determination of Gaseous H2O2 Using UV-Vis Spectroscopy

Vasko Jovanovski, Aaron Modic, Larisa Filip
article en
2 citations

Abstract

The detection of gases and volatile compounds remains a significant analytical challenge, particularly in terms of sensitivity and selectivity. Many situations require rapid, sensitive, and yet easy-to-operate methods for detecting gaseous hydrogen peroxide (H2O2) under ambient conditions. In this study, we present two novel methodologies for the real-time monitoring of gaseous H2O2 based on colorimetric reactions, which are quantitatively analysed using UV-vis spectrometry. The proposed methods demonstrate high sensitivity in the low mg m−3 range, with a broad linear response within the tested concentration ranges of 0.4–17.6 mg m−3 and 10–90 mg m−3 after 20 min of accumulation under room-temperature conditions. The simplicity of the experimental setup, combined with robust analytical performance, highlights the potential applications of these methods in emerging fields such as clinical diagnostics, explosives detection, environmental monitoring, and occupational health and safety.

ChemosensorsVol. 13(5)
University of Ljubljana (SI), National Institute of Chemistry (SI)
Javna Agencija za Raziskovalno Dejavnost RS
Openalex Percentile: Top 15%
Water Quality Monitoring and Analysis
1.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.