A Mechanism-Based Convex Model of Fuel Cell Systems Considering the Effect of Auxiliary System

Fuel cell systems (FCS) are recognized as promising electric sources of power systems. However, existing FCS models are either nonconvex or inaccurate when the FCS is under heavy load. This letter proposes a mechanism-based FCS feasible operational area (FCSFOA) model, taking into account the decline in fuel cell efficiency and the dynamic power consumption of the auxiliary system. Therefore, the FCSFOA model is accurate both under light load and heavy load, and the average error is only 5.4% compared with the actual data. In contrast, the FCS linear model, the most commonly used in the dispatch of power systems, has an average error of 24.4%. Besides, the FCSFOA model is also convex, which is favorable for the dispatch of power systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Sustainable Energy
Published
2025-04-24
DOI
https://doi.org/10.1109/tste.2025.3564106
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Mechanism-Based Convex Model of Fuel Cell Systems Considering the Effect of Auxiliary System

Haohui Ding, Qinran Hu, Yuze Wang, Jia Su et al.
IEEE Transactions on Sustainable Energy
Fuel Cells and Related Materials
article

A Mechanism-Based Convex Model of Fuel Cell Systems Considering the Effect of Auxiliary System

Haohui Ding, Qinran Hu, Yuze Wang, Jia Su, Cong Wang, Haizhou Liu
article en

Abstract

Fuel cell systems (FCS) are recognized as promising electric sources of power systems. However, existing FCS models are either nonconvex or inaccurate when the FCS is under heavy load. This letter proposes a mechanism-based FCS feasible operational area (FCSFOA) model, taking into account the decline in fuel cell efficiency and the dynamic power consumption of the auxiliary system. Therefore, the FCSFOA model is accurate both under light load and heavy load, and the average error is only 5.4% compared with the actual data. In contrast, the FCS linear model, the most commonly used in the dispatch of power systems, has an average error of 24.4%. Besides, the FCSFOA model is also convex, which is favorable for the dispatch of power systems.

IEEE Transactions on Sustainable EnergyVol. 16(4)
Jiangsu University of Technology (CN), Taiyuan University of Science and Technology (CN), Southeast University (CN), Taiyuan University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 93%
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Mechanism-Based Convex Model of Fuel Cell Systems Considering the Effect of Auxiliary System — Haohui Ding, Qinran Hu, et al. · IEEE Transactions on Sustainable Energy (2025) | TGRS Research Map | TGRS