Electric Anomaly Monitoring Model Based on Improved SVM

Aiming at the abnormal power consumption monitoring of smart grid, this paper puts forward a power abnormal monitoring model based on improved support vector machine (SVM), which can meet the needs of real-time monitoring while improving the detection accuracy and response speed. In this paper, the key electrical parameters, including voltage, current, power and frequency, are collected from smart meters and environmental sensors, and then the collected data are preprocessed to remove noise, deal with abnormal values and standardize the data. Then, in data preprocessing, the penalty parameter c of SVM model is optimized by radial basis function kernel. The experimental results show that the average detection delay of the improved SVM monitoring analysis is 287.36ms, and the highest detection coverage rate of the monitoring analysis is 99.5%, which reflects its efficiency and comprehensiveness in anomaly monitoring.

Authors

Institutions

Publication Details

Published
2025-02-21
DOI
https://doi.org/10.1109/icicacs65178.2025.10968962
Primary Topic
Anomaly Detection Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric Anomaly Monitoring Model Based on Improved SVM

W. Y. Huang, Ruobing Wu, Mengjue Sun
Anomaly Detection Techniques and Applications
article

Electric Anomaly Monitoring Model Based on Improved SVM

W. Y. Huang, Ruobing Wu, Mengjue Sun
article en

Abstract

Aiming at the abnormal power consumption monitoring of smart grid, this paper puts forward a power abnormal monitoring model based on improved support vector machine (SVM), which can meet the needs of real-time monitoring while improving the detection accuracy and response speed. In this paper, the key electrical parameters, including voltage, current, power and frequency, are collected from smart meters and environmental sensors, and then the collected data are preprocessed to remove noise, deal with abnormal values and standardize the data. Then, in data preprocessing, the penalty parameter c of SVM model is optimized by radial basis function kernel. The experimental results show that the average detection delay of the improved SVM monitoring analysis is 287.36ms, and the highest detection coverage rate of the monitoring analysis is 99.5%, which reflects its efficiency and comprehensiveness in anomaly monitoring.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 96%
Anomaly Detection Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electric Anomaly Monitoring Model Based on Improved SVM — W. Y. Huang, Ruobing Wu, et al. · (2025) | TGRS Research Map | TGRS