High Throughput Signal-Off-On Fluorescent Aptasensor for Pb<sup>2+</sup> Detection Based on Fluorescence Resonance Energy Transfer Between Graphite-Phase Carbon Nitride Nanosheets and Gold Nanoparticles

Heavy metal Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> is widely distributed in several environmental media, and exposure to Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> through various channels can seriously endanger the health of residents. Therefore, it is very important to detect Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> in high throughput, accurately and specifically. Fluorescent sensors have obvious advantages in heavy metal detection. In comparison with the bulk phase, graphite phase carbon nitride nanosheets (g-CNNs) of atomic thickness and nanometer size can conspicuously improve the quantum yield and water solubility. The aptamer offers the benefits of exceptional specificity, robust stability, minimal toxicity, cost-effectiveness, straightforward synthesis and modification, and absence of immunogenicity. In this study, an high throughput signal-off-on fluorescent aptasensor was designed for detecting Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> on the basis of fluorescence resonance energy transfer (FRET) mechanism between gold nanoparticles (AuNPs) and g-CNNs. Under the optimum experimental conditions, a linear correlation was established between (F-F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>)/F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> and Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> concentration within the range of 0 to 1000 μg/mL. The linear equation was (F-F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>)/F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>=0.0002C + 0.0278, with an R2 value of 0.9744 and the detection limit was 0.8 μg/mL. The proposed fluorescent aptasensor had strong anti-interference ability, high sensitivity and good reproducibility, and the recoveries of spiked samples were between 90.32% and 103.99%. The detection results of Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> in actual samples confirmed that this fluorescent aptasensor had good application potential.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-24
DOI
https://doi.org/10.1109/jsen.2025.3562314
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Throughput Signal-Off-On Fluorescent Aptasensor for Pb2+ Detection Based on Fluorescence Resonance Energy Transfer Between Graphite-Phase Carbon Nitride Nanosheets and Gold Nanoparticles

Shengzhong Rong, Feiyan Yang, Hongzhi Pan, Shanshan An et al.
IEEE Sensors Journal
Advanced biosensing and bioanalysis techniques
article

High Throughput Signal-Off-On Fluorescent Aptasensor for Pb2+ Detection Based on Fluorescence Resonance Energy Transfer Between Graphite-Phase Carbon Nitride Nanosheets and Gold Nanoparticles

Shengzhong Rong, Feiyan Yang, Hongzhi Pan, Shanshan An, Lina Zou, Lulu Jia, Yanan Liu, Zheng Li, Xiaojing Zhang, Hao Liao, Xuewu Ge, Fei Ren, Huanyu Ren, Lang Cheng, Huiru Niu, Hongkun Ma
article en

Abstract

Heavy metal Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> is widely distributed in several environmental media, and exposure to Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> through various channels can seriously endanger the health of residents. Therefore, it is very important to detect Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> in high throughput, accurately and specifically. Fluorescent sensors have obvious advantages in heavy metal detection. In comparison with the bulk phase, graphite phase carbon nitride nanosheets (g-CNNs) of atomic thickness and nanometer size can conspicuously improve the quantum yield and water solubility. The aptamer offers the benefits of exceptional specificity, robust stability, minimal toxicity, cost-effectiveness, straightforward synthesis and modification, and absence of immunogenicity. In this study, an high throughput signal-off-on fluorescent aptasensor was designed for detecting Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> on the basis of fluorescence resonance energy transfer (FRET) mechanism between gold nanoparticles (AuNPs) and g-CNNs. Under the optimum experimental conditions, a linear correlation was established between (F-F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>)/F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> and Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> concentration within the range of 0 to 1000 μg/mL. The linear equation was (F-F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>)/F<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>=0.0002C + 0.0278, with an R2 value of 0.9744 and the detection limit was 0.8 μg/mL. The proposed fluorescent aptasensor had strong anti-interference ability, high sensitivity and good reproducibility, and the recoveries of spiked samples were between 90.32% and 103.99%. The detection results of Pb<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> in actual samples confirmed that this fluorescent aptasensor had good application potential.

IEEE Sensors JournalVol. 25(11)
Mudanjiang Medical University (CN), Shanghai University of Medicine and Health Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 92%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.