Self-assembled nano-hybrid composite based on Cu/CuXO nanoflower decorated onto hBNNS for high-performance and ultra-sensitive electrochemical detection of CEA biomarker

Synergistic combination of metal/metal oxide with semiconductor as nano-hybrid composites (NHC), exhibits unmatched potential for developing nano-biosensors with superior stability, sensitivity, and selectivity. In this study, we report the fabrication of hydrothermally synthesized 3D2D NHC based on self-assembled Cu/Cu<sub>X</sub>O-hBNNS for label-free detection of Carcinoembryonic Antigen (CEA). A systematic investigation into the synthesis of Cu<sub>X</sub>O-NF, hBNNS, and Cu/Cu<sub>X</sub>O-hBNNS NHC was carried out using extensive spectroscopic and advanced nanoscale imaging techniques. Uniform deposition of Cu/Cu<sub>X</sub>O-hBNNS films onto pre-hydrolyzed ITO electrodes was achieved at a low DC potential of 15 V using electrophoretic deposition (EPD). Optimum immunoelectrode efficacy was analyzed by monitoring antibody incubation time, electrolyte pH, and control study through FTIR and electrochemical techniques. Electrode study revealed remarkably improved surface chemistry upon Cu/Cu<sub>X</sub>O integration with hBNNS, yielding ∼74 % and ∼ 31 % increase in CV and DPV response along with 3-fold increase in diffusion coefficient compared to bare hBNNS. The sensing response of the BSA/Anti-CEA/Cu/Cu<sub>X</sub>O-hBNNS/ITO nano-biosensor detected CEA concentrations from 0 to 50 ng/mL utilizing [Fe(CN<sub>6</sub>)<sup>3-/4-</sup>] as a redox probe and demonstrated an exceptionally low limit of detection of 3.22 pg/mL (R<sup>2</sup> = 0.99998). Electrochemical clinical evaluation supported by ELISA test established that Cu/Cu<sub>X</sub>O-hBNNS-based nano-biosensor demonstrates exceptional shelf life, low cross-reactivity, and superior recovery rates in human serum, highlighting its effectiveness for precise and reliable detection.

Authors

Institutions

Publication Details

Journal
Bioelectrochemistry
Published
2025-04-24
DOI
https://doi.org/10.1016/j.bioelechem.2025.108993
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-assembled nano-hybrid composite based on Cu/CuXO nanoflower decorated onto hBNNS for high-performance and ultra-sensitive electrochemical detection of CEA biomarker

Bharti Singh, Nitin K. Puri, Kanika Sharma
1 links
Bioelectrochemistry
Electrochemical sensors and biosensors
article

Self-assembled nano-hybrid composite based on Cu/CuXO nanoflower decorated onto hBNNS for high-performance and ultra-sensitive electrochemical detection of CEA biomarker

Bharti Singh, Nitin K. Puri, Kanika Sharma
article en

Abstract

Synergistic combination of metal/metal oxide with semiconductor as nano-hybrid composites (NHC), exhibits unmatched potential for developing nano-biosensors with superior stability, sensitivity, and selectivity. In this study, we report the fabrication of hydrothermally synthesized 3D2D NHC based on self-assembled Cu/Cu<sub>X</sub>O-hBNNS for label-free detection of Carcinoembryonic Antigen (CEA). A systematic investigation into the synthesis of Cu<sub>X</sub>O-NF, hBNNS, and Cu/Cu<sub>X</sub>O-hBNNS NHC was carried out using extensive spectroscopic and advanced nanoscale imaging techniques. Uniform deposition of Cu/Cu<sub>X</sub>O-hBNNS films onto pre-hydrolyzed ITO electrodes was achieved at a low DC potential of 15 V using electrophoretic deposition (EPD). Optimum immunoelectrode efficacy was analyzed by monitoring antibody incubation time, electrolyte pH, and control study through FTIR and electrochemical techniques. Electrode study revealed remarkably improved surface chemistry upon Cu/Cu<sub>X</sub>O integration with hBNNS, yielding ∼74 % and ∼ 31 % increase in CV and DPV response along with 3-fold increase in diffusion coefficient compared to bare hBNNS. The sensing response of the BSA/Anti-CEA/Cu/Cu<sub>X</sub>O-hBNNS/ITO nano-biosensor detected CEA concentrations from 0 to 50 ng/mL utilizing [Fe(CN<sub>6</sub>)<sup>3-/4-</sup>] as a redox probe and demonstrated an exceptionally low limit of detection of 3.22 pg/mL (R<sup>2</sup> = 0.99998). Electrochemical clinical evaluation supported by ELISA test established that Cu/Cu<sub>X</sub>O-hBNNS-based nano-biosensor demonstrates exceptional shelf life, low cross-reactivity, and superior recovery rates in human serum, highlighting its effectiveness for precise and reliable detection.

BioelectrochemistryVol. 165
NIIT (India) (IN), Delhi Technological University (IN)
Science and Engineering Research Board
Openalex Percentile: Top 93%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.