Optimizing airflow in double-skin facades: Influence of vents design and cavity depth

Despite the energy-saving potential of NVDSFs, this research examined the effectiveness of the Double-Skin Facade (DSF) system by optimizing its geometric configurations to enhance natural ventilation and indoor air quality in office buildings. Using Butterfly plugin inside grasshopper software, compared the performance of the DSF system to a base case without DSF in Amman, Jordan. The proposed scenarios demonstrated improvements in indoor air quality, increasing the actual-to-required ventilation ratio to 5.3, compared to 3.75 in the base case, according to American Society of Heating, Refrigerating, and Air-Conditioning Engineers) (ASHRAE 62) standards. Furthermore, identified locations with the lowest velocities and analyzed high-turbulence areas to optimize space use. The most important qualitative results were found that room corners, particularly near the inlet and outlet proposed openings, were found to be a high turbulence and were less acceptable to users.

Authors

Institutions

Publication Details

Journal
Cleaner Engineering and Technology
Published
2025-04-24
DOI
https://doi.org/10.1016/j.clet.2025.100980
Citations
1
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing airflow in double-skin facades: Influence of vents design and cavity depth

Shouib Nouh Ma’bdeh, Asia Ali Hamasha, Majd Al-Shawabkeh, Razan Omar Alali et al.
1 citations
Cleaner Engineering and Technology
Wind and Air Flow Studies
0.80
article

Optimizing airflow in double-skin facades: Influence of vents design and cavity depth

Shouib Nouh Ma’bdeh, Asia Ali Hamasha, Majd Al-Shawabkeh, Razan Omar Alali, Rahaf Mohammad Almomani
article en
1 citations

Abstract

Despite the energy-saving potential of NVDSFs, this research examined the effectiveness of the Double-Skin Facade (DSF) system by optimizing its geometric configurations to enhance natural ventilation and indoor air quality in office buildings. Using Butterfly plugin inside grasshopper software, compared the performance of the DSF system to a base case without DSF in Amman, Jordan. The proposed scenarios demonstrated improvements in indoor air quality, increasing the actual-to-required ventilation ratio to 5.3, compared to 3.75 in the base case, according to American Society of Heating, Refrigerating, and Air-Conditioning Engineers) (ASHRAE 62) standards. Furthermore, identified locations with the lowest velocities and analyzed high-turbulence areas to optimize space use. The most important qualitative results were found that room corners, particularly near the inlet and outlet proposed openings, were found to be a high turbulence and were less acceptable to users.

Cleaner Engineering and TechnologyVol. 26
Jordan University of Science and Technology (JO), University of Sharjah (AE), Hamad bin Khalifa University (QA)
Sustainable cities and communities
Openalex Percentile: Top 30%
Wind and Air Flow Studies
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing airflow in double-skin facades: Influence of vents design and cavity depth — Shouib Nouh Ma’bdeh, Asia Ali Hamasha, et al. · Cleaner Engineering and Technology (2025) | TGRS Research Map | TGRS