A simple and low-cost electrode based on Nafion-stabilized silver nanoparticles supported on FTO for the electrochemical determination of Pb (II) and Cu (II)

Increasing awareness of the environmental risks posed by heavy metal accumulation in the environment-due to their toxicity and persistence in biological systems-has driven the development of more efficient and accessible detection methods. Conventional techniques, despite their accuracy, are often expensive, time-consuming, and reliant on non-portable specialized equipment. This study presents a novel, low-cost electrochemical sensor using a fluorine-doped tin oxide (FTO) electrode modified with Nafion-stabilized silver nanoparticles (AgNPs) for the rapid and accurate detection of Pb (II) and Cu (II) in water samples. The electrode preparation involved the ultrasonic cleaning of the FTO, followed by its surface modification with Nafion and the electrodeposition of AgNPs. Electrochemical and structural characterization confirmed the advantages of this approach, showing a significant improvement in conductivity and in the active surface area of the electrode, which allowed for the sensitive detection of the target metals. The optimization of analytical parameters, including accumulation time, deposition potential, and pH, facilitated the effective determination of the analytes by differential pulse anodic stripping voltammetry (DPV). The results demonstrated low detection limits of 8.87 ppb for Pb (II) and 3.26 ppb for Cu (II), suitable for in-situ applications in environmental monitoring according to environmental quality standards. The sensor's portability, coupled with its low cost and rapid analysis capability, addresses critical challenges in current monitoring practices and opens new avenues for widespread environmental surveillance in remote areas such as the Andean regions, where heavy metal contamination is a significant concern.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-04-24
DOI
https://doi.org/10.1371/journal.pone.0320227
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simple and low-cost electrode based on Nafion-stabilized silver nanoparticles supported on FTO for the electrochemical determination of Pb (II) and Cu (II)

Wilner Valenzuela Barrientos, Kelly L.S. Castro, Patricia Sheen, Mirko Zimic et al.
PLoS ONE
Electrochemical Analysis and Applications
article

A simple and low-cost electrode based on Nafion-stabilized silver nanoparticles supported on FTO for the electrochemical determination of Pb (II) and Cu (II)

Wilner Valenzuela Barrientos, Kelly L.S. Castro, Patricia Sheen, Mirko Zimic, Raúl León, Alen Zimic-Sheen, Leonardo J Monroy-Cruz, Akemi Morales-Kato, Yndira Dolores-Maldonado, María Belén Balta, Geraldine J Otayza-Melgarejo
article en

Abstract

Increasing awareness of the environmental risks posed by heavy metal accumulation in the environment-due to their toxicity and persistence in biological systems-has driven the development of more efficient and accessible detection methods. Conventional techniques, despite their accuracy, are often expensive, time-consuming, and reliant on non-portable specialized equipment. This study presents a novel, low-cost electrochemical sensor using a fluorine-doped tin oxide (FTO) electrode modified with Nafion-stabilized silver nanoparticles (AgNPs) for the rapid and accurate detection of Pb (II) and Cu (II) in water samples. The electrode preparation involved the ultrasonic cleaning of the FTO, followed by its surface modification with Nafion and the electrodeposition of AgNPs. Electrochemical and structural characterization confirmed the advantages of this approach, showing a significant improvement in conductivity and in the active surface area of the electrode, which allowed for the sensitive detection of the target metals. The optimization of analytical parameters, including accumulation time, deposition potential, and pH, facilitated the effective determination of the analytes by differential pulse anodic stripping voltammetry (DPV). The results demonstrated low detection limits of 8.87 ppb for Pb (II) and 3.26 ppb for Cu (II), suitable for in-situ applications in environmental monitoring according to environmental quality standards. The sensor's portability, coupled with its low cost and rapid analysis capability, addresses critical challenges in current monitoring practices and opens new avenues for widespread environmental surveillance in remote areas such as the Andean regions, where heavy metal contamination is a significant concern.

PLoS ONEVol. 20(4)
Peruvian University of Applied Sciences (PE), Universidad Peruana Cayetano Heredia (PE), National University of Engineering (PE)
Life in Land
Openalex Percentile: Top 91%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.