A Rare Complication of Robot-Assisted Total Knee Replacement: Spontaneous Recurrent Hemarthrosis and Its Management
Spontaneous recurrent hemarthrosis following total knee replacement is a relatively rare complication. It requires a different and swift management plan compared to any other knee swelling. Presentation can vary from 2 months to 1.5 years, and it can lead to further complications, including a limited range of movement and severe stiffness, resulting in compromised functionality. Although etiology is not well understood, it can be due to instrumentation leading to direct vessel injury, including popliteal and geniculate arteries, arteriovenous fistula, and pseudoaneurysms. This case report aims to contribute to the early identification and management of this rare complication. We present a case involving the early onset of recurrent spontaneous hemarthrosis following robot-assisted total knee replacement surgery.
Authors
- M Zain-Ur-Rehman
- Corinna Winkworth
- Rahul Chivate
- Nadim Aslam
Institutions
- Worcestershire Acute Hospitals NHS Trust (GB)
Publication Details
- Journal
- Cureus
- Published
- 2025-04-24
- DOI
- https://doi.org/10.7759/cureus.82933
- Primary Topic
- Musculoskeletal synovial abnormalities and treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00