Static VAr Compensator Control Using Phasor Measurement Unit Feedback Signals for Voltage Stability Improvement in Power Systems

ABSTRACT Demand for electric power is constantly increasing, resulting in enormous rapid growth and adding high stress to the grid. The transmission system is a vital part of power systems; however, it is not expanding at the same rate as the demand. Therefore, the grid requires a more capable transmission network to meet growing demand. Flexible Alternating Current Transmission System (FACTS) devices play a crucial role in the efficient and reliable operation of the power systems. They provide reactive power compensation, improving voltage stability, and increasing the transmission capability of existing transmission lines. Static Var Compensators (SVCs), a type of FACTS device, can be effectively used to improve the voltage profile in the system. Furthermore, Phasor measurement units (PMUs) are essential for power system monitoring, control, and protection. Their high data rates make them ideal for accurately measuring electrical signals, including voltage or current, thus providing synchronized measurements throughout the grid. With the increasing complexity of power grids, maintaining voltage stability has emerged as a critical challenge in modern power systems. Traditional SVC control often depends on delayed or indirect measurements, restricting their response time and effectiveness. PMUs provide high‐speed, synchronized data, and their direct integration with SVC controllers for voltage regulation remains underexplored. This study bridges this gap and presents a method for controlling the SVC using a combination of multiple control modes while obtaining real‐time system measurements using PMUs. Results show that our method significantly improves voltage stability, as witnessed by an improved voltage profile and settling time under various disturbances.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2025-04-23
DOI
https://doi.org/10.1002/ese3.70114
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Static VAr Compensator Control Using Phasor Measurement Unit Feedback Signals for Voltage Stability Improvement in Power Systems

Ayman Faza, Faris Alsalem
Energy Science & Engineering
Power System Optimization and Stability
article

Static VAr Compensator Control Using Phasor Measurement Unit Feedback Signals for Voltage Stability Improvement in Power Systems

Ayman Faza, Faris Alsalem
article en

Abstract

ABSTRACT Demand for electric power is constantly increasing, resulting in enormous rapid growth and adding high stress to the grid. The transmission system is a vital part of power systems; however, it is not expanding at the same rate as the demand. Therefore, the grid requires a more capable transmission network to meet growing demand. Flexible Alternating Current Transmission System (FACTS) devices play a crucial role in the efficient and reliable operation of the power systems. They provide reactive power compensation, improving voltage stability, and increasing the transmission capability of existing transmission lines. Static Var Compensators (SVCs), a type of FACTS device, can be effectively used to improve the voltage profile in the system. Furthermore, Phasor measurement units (PMUs) are essential for power system monitoring, control, and protection. Their high data rates make them ideal for accurately measuring electrical signals, including voltage or current, thus providing synchronized measurements throughout the grid. With the increasing complexity of power grids, maintaining voltage stability has emerged as a critical challenge in modern power systems. Traditional SVC control often depends on delayed or indirect measurements, restricting their response time and effectiveness. PMUs provide high‐speed, synchronized data, and their direct integration with SVC controllers for voltage regulation remains underexplored. This study bridges this gap and presents a method for controlling the SVC using a combination of multiple control modes while obtaining real‐time system measurements using PMUs. Results show that our method significantly improves voltage stability, as witnessed by an improved voltage profile and settling time under various disturbances.

Energy Science & EngineeringVol. 13(7)
Princess Sumaya University for Technology (JO)
Openalex Percentile: Top 93%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Static VAr Compensator Control Using Phasor Measurement Unit Feedback Signals for Voltage Stability Improvement in Power Systems — Ayman Faza, Faris Alsalem · Energy Science & Engineering (2025) | TGRS Research Map | TGRS