Clean environmental strategy applied to anatomy laboratory wastewater purification: a hybrid and integrated performance of a photo-electro-Fered-Fenton process

• Formaldehyde: Environmental and public health concerns. • Advanced Oxidation Processes (AOPs) combined: UVC/AO/H 2 O 2 /O 3 . • Acute toxicity increase of ALW-CFA evaluated by Artemia salina . • The natural pH of ALW-CFA favors oxidative radical generation by H 2 O 2 and O 3 . Formaldehyde (CH 2 O) is an important preservative of anatomic pieces in laboratories; Solutions with high concentrations of CH 2 O are used to avoid the deterioration of anatomic pieces. Besides the high concentration of CH 2 O, organic content may leachate from the material stored in the tanks, increasing the complexity of the wastewater generated. The anatomy laboratory wastewater with high formaldehyde concentration (ALW-CFA) presents potential toxic effects to humans and the ecosystem in general, for this reason, proper treatment is demanded before its discharge. In the present work, the degradation of CH 2 O and reduction of toxicity levels of ALW-CFA samples were studied through the application of the process photo-electro-Fered-Fenton process (PEF-Fered). The suitable operational conditions of the process PEF-Fered such as initial solution pH, current intensity, and H 2 O 2 initial concentration, were studied by the application of an RSM evaluating the reduction of concentrations of CH 2 O and TOC. Then, the increment of O 3 to the PEF-Fered process was performed (PEF-Fered-O 3 ), aiming to increase the oxidative potential of the system. However, it was observed that the use of many oxidative inputs at the same time (hybrid process) was not interesting for the ALW-CFA degradation, thus, the best treatment strategy which provided a lower toxicity level (LC 50 % = 56.94) was the AO followed by H 2 O 2 and O 3 , with a removal of 90 % of CH 2 O and 85 % of TOC, under the following operational conditions, solution pH 4.5; the current intensity of 2.4 and H 2 O 2 concentration of 24,000 mg l -1 . With the application of the advanced combined treatment, the pollution potential of this wastewater was reduced, evidencing the protection of human health and ecosystems in general.

Authors

Institutions

Publication Details

Journal
Cleaner Chemical Engineering
Published
2025-04-24
DOI
https://doi.org/10.1016/j.clce.2025.100175
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clean environmental strategy applied to anatomy laboratory wastewater purification: a hybrid and integrated performance of a photo-electro-Fered-Fenton process

Daiana Seibert, Liziara C. Cabrera, Fernando Henrique Borba, Camila F. Zorzo et al.
Cleaner Chemical Engineering
Advanced oxidation water treatment
article

Clean environmental strategy applied to anatomy laboratory wastewater purification: a hybrid and integrated performance of a photo-electro-Fered-Fenton process

Daiana Seibert, Liziara C. Cabrera, Fernando Henrique Borba, Camila F. Zorzo, Jonas J. Inticher, Nicóli Justen, Matteo Zago
article en

Abstract

• Formaldehyde: Environmental and public health concerns. • Advanced Oxidation Processes (AOPs) combined: UVC/AO/H 2 O 2 /O 3 . • Acute toxicity increase of ALW-CFA evaluated by Artemia salina . • The natural pH of ALW-CFA favors oxidative radical generation by H 2 O 2 and O 3 . Formaldehyde (CH 2 O) is an important preservative of anatomic pieces in laboratories; Solutions with high concentrations of CH 2 O are used to avoid the deterioration of anatomic pieces. Besides the high concentration of CH 2 O, organic content may leachate from the material stored in the tanks, increasing the complexity of the wastewater generated. The anatomy laboratory wastewater with high formaldehyde concentration (ALW-CFA) presents potential toxic effects to humans and the ecosystem in general, for this reason, proper treatment is demanded before its discharge. In the present work, the degradation of CH 2 O and reduction of toxicity levels of ALW-CFA samples were studied through the application of the process photo-electro-Fered-Fenton process (PEF-Fered). The suitable operational conditions of the process PEF-Fered such as initial solution pH, current intensity, and H 2 O 2 initial concentration, were studied by the application of an RSM evaluating the reduction of concentrations of CH 2 O and TOC. Then, the increment of O 3 to the PEF-Fered process was performed (PEF-Fered-O 3 ), aiming to increase the oxidative potential of the system. However, it was observed that the use of many oxidative inputs at the same time (hybrid process) was not interesting for the ALW-CFA degradation, thus, the best treatment strategy which provided a lower toxicity level (LC 50 % = 56.94) was the AO followed by H 2 O 2 and O 3 , with a removal of 90 % of CH 2 O and 85 % of TOC, under the following operational conditions, solution pH 4.5; the current intensity of 2.4 and H 2 O 2 concentration of 24,000 mg l -1 . With the application of the advanced combined treatment, the pollution potential of this wastewater was reduced, evidencing the protection of human health and ecosystems in general.

Cleaner Chemical EngineeringVol. 11
Universidade Estadual do Oeste do Paraná (BR), Universidade Federal da Fronteira Sul (BR)
Clean water and sanitation
Openalex Percentile: Top 91%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.