Quantum-CMOS image sensor assessment for Cherenkov imaging during radiotherapy

Cherenkov emission from human tissues during linac-delivered radiotherapy provides a detectable optical signal that shows the real-time dose delivery. The challenge of this modality is that the linac pulses producing Cherenkov light have short durations (2–4 μs) with low duty cycle (0.1%), and the signal reaches the camera with near single photon per pixel intensity. In this study, the ability to use an ultra-low noise (<1 e − /pixel) quantum-CMOS sensor (qCMOS) to detect Cherenkov light was tested, with optimization of the signal integration and readout timings, as related to the linac pulse structure. The signal-to-noise ratio (SNR) of the detected Cherenkov was found to be sufficient for good image quality with SNR values ranging from 100 up to 400, depending on the exposure time set per frame with noise performance surpassing an intensifier-coupled CMOS camera (iCMOS) beyond ∼50 ms of exposure time per frame. The detected signal also correlated very closely to a planned dose in a water tank with gamma pass rates of >94%. Additional advantages include low susceptibility to stray x-ray radiation. This recent development of ultra-low noise qCMOS technology is a unique option for Cherenkov imaging, showing the ability to image signals well above the noise without need for image intensifiers or gain amplification.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-04-24
DOI
https://doi.org/10.1364/ol.553775
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantum-CMOS image sensor assessment for Cherenkov imaging during radiotherapy

Petr Brůža, Jeremy Eric Hallett, Brian W. Pogue
Optics Letters
Radiation Detection and Scintillator Technologies
article

Quantum-CMOS image sensor assessment for Cherenkov imaging during radiotherapy

Petr Brůža, Jeremy Eric Hallett, Brian W. Pogue
article en

Abstract

Cherenkov emission from human tissues during linac-delivered radiotherapy provides a detectable optical signal that shows the real-time dose delivery. The challenge of this modality is that the linac pulses producing Cherenkov light have short durations (2–4 μs) with low duty cycle (0.1%), and the signal reaches the camera with near single photon per pixel intensity. In this study, the ability to use an ultra-low noise (<1 e − /pixel) quantum-CMOS sensor (qCMOS) to detect Cherenkov light was tested, with optimization of the signal integration and readout timings, as related to the linac pulse structure. The signal-to-noise ratio (SNR) of the detected Cherenkov was found to be sufficient for good image quality with SNR values ranging from 100 up to 400, depending on the exposure time set per frame with noise performance surpassing an intensifier-coupled CMOS camera (iCMOS) beyond ∼50 ms of exposure time per frame. The detected signal also correlated very closely to a planned dose in a water tank with gamma pass rates of >94%. Additional advantages include low susceptibility to stray x-ray radiation. This recent development of ultra-low noise qCMOS technology is a unique option for Cherenkov imaging, showing the ability to image signals well above the noise without need for image intensifiers or gain amplification.

Optics LettersVol. 50(10)
Dartmouth College (US), DoseOptics (United States) (US)
Openalex Percentile: Top 90%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.