Analisis Risiko Penyebab Kegagalan Pipa Penyalur Crude Oil

The distribution pipe refers to API 5L Grade B standard, 8 inches in diameter, has a length of 212 km. The design life of pipe is 20 years, but after being operated, there were two leaks in this segment in one year. This condition resulted in disruption of oil deliveries. Research is needed to determine the cause of pipe failure before its design life. Pipe samples are subjected to visual observation, thickness test, chemical composition of the pipe, microstructure test, Characterization test of pipe corrosion product deposits. Produced water are testing to determine anions, cations and the tendency for scale formation with Valone & Skillern references. The visual test results showed that the inside of the pipe was thinning at 6 o'clock. Chemical composition testing showed that there was no difference in chemical composition with API 5L Grade B standards. SEM results in the leak area revealed the corrosion morphology caused by dissolved CO2. XRD analysis of the corrosion deposits formed were siderite (Fe2CO3), hematite (Fe3O4) and iron (Fe) compounds. Pipe failure occurs due to corrosive substances in the form of produced water. This situation causes the surface of the pipe to be exposed to produced water at the 6' o'clock position, initiating the formation of hydrogen ions (H+) and ions (HCO3-).

Authors

Institutions

Publication Details

Journal
Jurnal Teknik Mesin Elektro dan Ilmu Komputer
Published
2025-03-30
DOI
https://doi.org/10.55606/teknik.v5i1.5732
Primary Topic
Heavy Metal Pollution Remediation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Risiko Penyebab Kegagalan Pipa Penyalur Crude Oil

Rochim Bakti Cahyono, Teguh Santoso, Rifki Adrian, Rizal Fazaul M
Jurnal Teknik Mesin Elektro dan Ilmu Komputer
Heavy Metal Pollution Remediation
article

Analisis Risiko Penyebab Kegagalan Pipa Penyalur Crude Oil

Rochim Bakti Cahyono, Teguh Santoso, Rifki Adrian, Rizal Fazaul M
article en

Abstract

The distribution pipe refers to API 5L Grade B standard, 8 inches in diameter, has a length of 212 km. The design life of pipe is 20 years, but after being operated, there were two leaks in this segment in one year. This condition resulted in disruption of oil deliveries. Research is needed to determine the cause of pipe failure before its design life. Pipe samples are subjected to visual observation, thickness test, chemical composition of the pipe, microstructure test, Characterization test of pipe corrosion product deposits. Produced water are testing to determine anions, cations and the tendency for scale formation with Valone & Skillern references. The visual test results showed that the inside of the pipe was thinning at 6 o'clock. Chemical composition testing showed that there was no difference in chemical composition with API 5L Grade B standards. SEM results in the leak area revealed the corrosion morphology caused by dissolved CO2. XRD analysis of the corrosion deposits formed were siderite (Fe2CO3), hematite (Fe3O4) and iron (Fe) compounds. Pipe failure occurs due to corrosive substances in the form of produced water. This situation causes the surface of the pipe to be exposed to produced water at the 6' o'clock position, initiating the formation of hydrogen ions (H+) and ions (HCO3-).

Jurnal Teknik Mesin Elektro dan Ilmu KomputerVol. 5(1)
Universitas Gadjah Mada (ID)
Openalex Percentile: Top 91%
Heavy Metal Pollution Remediation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.