Condition Monitoring Method and Evaluation of Gun Recuperator

The technical state of counter recoil mechanism is the key index affecting the health state of artillery. It mainly monitors the technical status of the recoil mechanism by detecting the air pressure and liquid volume of the recoil mechanism.The Gun Recuperator is a multi-layer nested high-pressure closed container, which is filled with recoil liquid and compressed nitrogen. The air pressure is detected by a pressure sensor. On the premise of changing the internal volume of the counter recoil mechanism, the pressure signal is measured, and then converted by the intelligent instrument. There are some methods to measure the liquid volume of the recuperator, and the performance of each method varies greatly. By summarizing and analyzing the current liquid volume measurement methods on recuperator,and the fuzzy calculation method is used to evaluate its comprehensive performance, The results show that the air-source closed detection method has the best comprehensive performance, followed by the electric pump source open injection and discharge method. This result provides a preferred basis for decision makers to select the appropriate detection method.

Authors

Publication Details

Published
2025-04-23
DOI
https://doi.org/10.58286/31050
Citations
1
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Condition Monitoring Method and Evaluation of Gun Recuperator

Guangsheng Liu, Lin Gan, Chao Han
1 citations
Advanced Measurement and Detection Methods
0.73
article

Condition Monitoring Method and Evaluation of Gun Recuperator

Guangsheng Liu, Lin Gan, Chao Han
article en
1 citations

Abstract

The technical state of counter recoil mechanism is the key index affecting the health state of artillery. It mainly monitors the technical status of the recoil mechanism by detecting the air pressure and liquid volume of the recoil mechanism.The Gun Recuperator is a multi-layer nested high-pressure closed container, which is filled with recoil liquid and compressed nitrogen. The air pressure is detected by a pressure sensor. On the premise of changing the internal volume of the counter recoil mechanism, the pressure signal is measured, and then converted by the intelligent instrument. There are some methods to measure the liquid volume of the recuperator, and the performance of each method varies greatly. By summarizing and analyzing the current liquid volume measurement methods on recuperator,and the fuzzy calculation method is used to evaluate its comprehensive performance, The results show that the air-source closed detection method has the best comprehensive performance, followed by the electric pump source open injection and discharge method. This result provides a preferred basis for decision makers to select the appropriate detection method.

Openalex Percentile: Top 29%
Advanced Measurement and Detection Methods
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Condition Monitoring Method and Evaluation of Gun Recuperator — Guangsheng Liu, Lin Gan, et al. · (2025) | TGRS Research Map | TGRS