Examining the Existing Criteria for the Evaluation of Window Ejected Plume Attachment
Both single-skin and double-skin glass facades are extensively employed in commercial high-rise buildings and are gaining increasing popularity. However, the capability to deploy firefighting agents in such ultra-high structures remains limited and has been minimally investigated. To provide guidance for single-layer exterior wall fire protection, this study examines the impact of vertical walls on window ejected plumes by simulating the upper portion of jet plumes using a square burner flame. Experimental and numerical simulations were conducted. The findings revealed that plumes from propane burners could attach to the wall even when LE. burner fire > 0.7W, contradicting previous criteria. This discrepancy arises because prior studies underestimated the induced pressure difference in large fires. This pressure difference propels the plume toward the wall, behaving like a rigid body.
Authors
- Lei Miao (ORCID: https://orcid.org/0000-0002-1023-7066)
- Bin Zheng (ORCID: https://orcid.org/0000-0003-3476-5936)
- Jianlong Xing
- Chaoting Nie
Institutions
- Wuhan University of Technology (CN)
Publication Details
- Journal
- Fire
- Published
- 2025-04-23
- DOI
- https://doi.org/10.3390/fire8050168
- Primary Topic
- Evacuation and Crowd Dynamics
- Type
- article
- Field-Weighted Citation Impact
- 0.00